Query :MACHine{1|2}:STRigger:TERM?
<term_id>,<label_name>
The TERM query returns the specification of the term specified by term
identification and label name.
Returned Format [:MACHine{1|2}:STRAce:TERM]
<term_id>,<label_name>,<pattern><NL>
Example OUTPUT XXX;":MA CHINE1:STRIG GER:TERM? B,’DATA’ "
TIMER Command :MACHine{1|2}:STRigger:TIMER{1|2} <time_value>
The TIMER command sets the time value for the specified timer. The limits
of the timer are 400 ns to 500 seconds in 16 ns to 500 µs increments. The
increment value varies with the time value of the specified timer. There are
two timers and they are independently available for either machine. Neither
timer can be assigned to both machines simultaneously.
<time_value> A real number from 400 ns to 500 seconds in increments which vary from 16
ns to 500 µs.
Example OUTPUT XXX;":MA CHINE1:STRIG GER:TIMER1 100 E−6"
STRigger (STRace) Subsystem
TIMER