CLRStat
Command :MACHine{1|2}:SWAVeform:CLRStat
The CLRStat command allows you to clear the waveform statistics without
having to stop and restart the acquisition.
Example OUTPUT XXX;":MA CHINE1:SWAVE FORM:CLRSTAT "
DELay
Command :MACHine{1|2}:SWAVeform:DELay <number_of_samples>
The DELay command allows you to specify the number of samples between
the State trigger and the horizontal center of the screen for the waveform
display. The allowed number of samples is from 8191 to +8191.
<number_of_
samples>
integer from –8191 to +8191
Example OUTPUT XXX;":MA CHINE2:SWAVE FORM:DELAY 127 "
Query :MACHine{1|2}:SWAVeform:DELay?
The DELay query returns the current sample offset value.
Returned Format [:MACHine{1|2}:SWAVeform:DELay] <number_of_samples><NL>
<number_of_
samples>
integer from –8191 to +8191
Example OUTPUT XXX;":MA CHINE1:SWAVE FORM:DELAY?"
SWAVeform Subsystem
CLRStat
18–7