Query :MARKer:MSTats?
The MSTats query returns the current setting.
Returned Format [:MARKer:MSTats]{1|0}<NL>
Example OUTPUT XXX;":MA RKER:MSTATS? "
OAUTo
Command :MARKer:OAU To{ MANual |CHANnel<N >,<type>,< level>,

<slope>,<occurrence>}

The OAUTo command specifies the automatic placement specification for
the O marker. The first parameter specifies if automarker placement is to be
in the manual mode or on a specified channel. If a channel is specified, four
other parameters must be included in the command syntax. The four
parameters are: marker type, level, the slope, and the occurrence count.
<N> An integer from 1 to 2
<type> ABSolute or PERCent
<level> percentage of waveform voltage level, ranging from 10 to 90 of the Vtop to
Vbase voltage or a voltage level
<slope> POSitive or NEGative
<occurrence> integer from 1 to 100
Example OUTPUT XXX;":MARKER:OAUTO CHANNEL1,PERCent,50,POSITIVE,5"
MARKer Subsystem
OAUTo
31-9