Table 19-1 SCHart Parameter Values
Parameter Values
state_low_value integer from 8191 to +8191
state_high_value integer from <state_low_value> to +8191
label_name string of up to 6 alphanumeric characters
label_low_value string from 0 to 232 1 (#HFFFF)
label_high_value string from <label_low_value> to 232 1 (#HFFFF)
low_value string from 0 to 232 1 (#HFFFF)
high_value string from low_value to 232 1 (#HFFFF)
SCHart
Selector :MACHine{1|2}:SCHart
The SCHart selector is used as part of a compound header to access the
settings found in the State Chart menu. It always follows the MACHine
selector because it selects a branch below the MACHine level in the
command tree.
Example OUTPUT XXX;":MA CHINE1:SCHAR T:VAXIS A, 0, 9"
ACCumulate
Command :MACHine{1|2}:SCHart:ACCumulate {{ON|1}|{OFF|0}}
The ACCumulate command allows you to control whether the chart display
gets erased between each individual run or whether subsequent waveforms
are allowed to be displayed over the previous waveforms.
SCHart Subsystem
SCHart
19–4