Query :MACHine{1|2}:STRigger:TIMER{1|2}?
The TIMER query returns the current time value for the specified timer.
Returned Format [:MACHine{1|2}:STRigger:TIMER{1|2}] <time_value><NL>
<time_value> A real number from 400 ns to 500 seconds in increments which vary from 16
ns to 500 µs.
Example OUTPUT XXX;":MA CHINE1:STRIG GER:TIMER1?"
TPOSition
Command :MACHine{1|2}:STRigger:TPOSition
{STARt|CENTer|END|POSTstore,<poststore>}
The TPOSition (trigger position) command allows you to set the trigger at
the start, center, end or at any position in the trace (poststore). When STARt
is specified, approximately 16 states are stored before the trigger. When
END is specified, approximately 16 states are stored after the trigger.
Poststore is defined as 0 to 100 percent. When 0 or 100 percent is specified,
the trigger is actually the first or last state respectively.
<poststore> An integer from 0 to 100 representing percentage of poststore.
Examples OUTPUT XXX;":MACH INE1:STRIGGE R:TPOSITION EN D"
OUTPUT XXX;": MACHINE1:STR IGGER:TPOSIT ION POSTstore, 75"
STRigger (STRace) Subsystem
TPOSition
16–23