Cable Testing in Expert Mode 5
The Expert Autotest Setup
Agilent FrameScope350 User’s Manual 125
2On the Autotest Setup screen, press Edit Settings. The Autotest
Settings screen shows a menu of parameters and functions.
3Press the name of the probe, then press View. The Probe Information
screen displays, with information on the probe inserted in the
FrameScope.
4If you desire to check the probe test count before each test, press
Check Probe Test Count and enter the limit to be tested against.
5To view information on the probe installed in the DualRemote, press
the DualRemote tab. The Probe Information screen displays
information about the probe in the DualRemote after running an
Autotest.
6If you desire to check the DualRemote probe test count before each
test, press Check Probe Test Count and enter the limit to be tested
against.
Setting Network Limits

The FrameScope 350 can determine compliance with signal to

noise ratio (SNR) requirements for a variety of popular LAN

technologies. To do this:

1In Expert Mode, press Autotest on the Main Menu. The Autotest
Settings screen displays.
2On the Autotest Setup screen press Edit Settings.
3On the Autotest Settings screen press Network Limits. Then press
Edit.
4On the Networks Setup screen press on the appropriate technology
for which you want to certify the tested cabling. A red check will
appear in each technology selected. Other includes a variety of
legacy network standards.