212 Agilent FrameScope350 User’s Manual
9Cable Tester Reference
Measurements
Measurements
The FrameScope 350 makes the following test measurements. See
“Setting the Measurements” on page129 for more details.

Wiremap

Wiremap testing checks for proper continuity and termination of cables.
The test identifies the following faults:
Short circuit
Open circuit
Reversed pairs
Transposed pairs
Split pairs
Shield continuity faults

Length

Length measurements determine the electrical length of cable runs up to
1100feet (335 meters). Accurate length measurements require accurate
NVP settings. Choosing a cable type from the FrameScope’s database
automatically loads NVP settings, or the NVP for a cable can be
measured on a sample (“Learning the NVP of a Cable” on page138).

Propagation Delay and Skew

The Propagation Delay test measures the one-way propagation delay
over each pair of the tested cable run. Skew is the difference in
propagation delay between the pairs with the longest and shortest delay
in a cable.
± ±
±
± ±
±