5Cable Testing in Expert Mode

Running COAX and TWINAX Autotests

cable is automatically selected. Press the Edit Settings button to change any settings.

2Press the Start Test button from the Autotest Setup screen to perform the Twinax Autotest

Results

The Twinax Autotest evaluates length and cable integrity. Twinax cable integrity includes the detection of a properly connected shield. These results are shown in both the diagram at the top of the screen and the table at the bottom. Delay and NVP information are also shown. Pressing the Details button shows more information about the test.

144

Agilent FrameScope 350 User’s Manual

Page 152
Image 152
Agilent Technologies N2610A user manual 144