3Cable Testing with the FrameScope 350

Setting Up an Autotest

Setting Up an Autotest

The tester must be configured for testing at each site by completing the following procedures.

Opening the Setup Menu

1On the Main Menu, press Setup. The Autotest Setup screen displays.

Choosing the Profile

The FrameScope 350 normally displays one or two limit options on the Main Menu, based upon the profile selected. If None is selected, then the two limit options are dependent upon the Standard selected. If the Standard is TIA-568B, then the two limit options are Category 5E and Category 6. Otherwise Class D and Class E are displayed. If the profile for a specific test is selected, then only that test choice is displayed. To change the profile:

1On the Autotest Setup screen, press Profile, then Edit. The Profile Setup screen displays.

2Press None, or the profile of choice, then press OK. The Autotest Setup screen will then show your selected profile.

Choosing the Standard

The FrameScope 350 normally tests to the TIA-568B standard. (For detailed information about test standards, please visit the website at: http://FrameScope.comms.agilent.com/ ) To test to a different standard, follow these steps:

62

Agilent FrameScope 350 User’s Manual

Page 70
Image 70