4Fiber Testing

Setting Up an Autotest

Choosing the Cable Type

Cable from different manufacturers has different transmission characteristics. The FrameScope 350 compensates for those differences if you tell it what cable is used on the job. The color of the cable spool icon indicates multimode (orange) or singlemode (yellow) fiber.

1On the Fiber Autotest Settings screen, press the spool icon, then press Edit. The Cable Setup screen displays.

2Select the cable manufacturer, and press Next. The Cable Database screen displays.

3Select a cable on the list, and press OK. The Fiber Autotest Setup screen displays, with the selected cable type next to the spool icon. If you do not see the cable on list, see the next section.

Adding a new cable type

If you have a cable which is not in the cable database, you can add a new cable description to the database.

1If the manufacturer is not present, leave the manufacturer as Unspecified. If the manufacturer is present in the list, select it, then press Next. The Cable Database screen is displayed. In either case you will be offered stored descriptions of cable types. If one of the stored descriptions matches the cable being tested select it, then press OK.

2If not highlight Add New Description and press Next.

3Enter the name to be added to the database and press Next.

108

Agilent FrameScope 350 User’s Manual

Page 116
Image 116
Agilent Technologies N2610A user manual 108