
7System Operations
Network Settings
Network Settings
The Network Settings screen shows a summary of the network configuration. This screen may also be accessed by pressing on the FrameScope icon on the right of the Main Menu. This includes the following:
The Network Settings screen can be reached by pressing on the
FrameScope Icon on the Network tab Main Menu or by pressing
System from the Network tab Main Menu and then pressing
Network Settings and then Edit.
The information displayed includes Host Name (FrameScope 350 name, which by default is FRSCOPE plus the last three hex bytes of the MAC address, but it can be changed,) MAC address of the FrameScope 350 (This is a factory setting that identifies FrameScope uniquely among all Ethernet devices.), information assigned by DHCP or manually, Network Connection (Auto or Manual,) and whether Active Discovery and Measure Length are enabled or disabled. To change any of the settings, press Edit
Settings.
IP Settings The first Network Settings Setup screen allows you to select using DHCP to automatically configure the FrameScope when connected to the network, or to manually configure. If you manually configure, you are required to at least enter a valid IP address and a valid subnet mask.
•IP Address – This value uniquely identifies the FrameScope in the TCP/IP network.
•Subnet Mask – This value is combined with the IP Address to define the subnet to which the FrameScope belongs.
170 | Agilent FrameScope 350 User’s Manual |