Fiber Testing

4

Calibrating the Tester

7When the message below the diagram reads, “Ready to Calibrate,” press OK. The Calibration window opens.

8When the window reads, “Calibration Successful,” press OK in the window. The Fiber Main Menu displays. Remove the reference jumper to start testing.

Calibrating for Single-Ended Testing

1Insert a Fiber SmartProbe+ in the FrameScope,.

2Connect a test jumper to the Fiber SmartProbe+.

3Connect the two ends of the test jumper to each other, using a coupler.

4Turn on the FrameScope.

The FrameScope detects a Fiber SmartProbe+, and displays the following window:

5On the Fiber Main Menu, press Calibration. The Fiber Calibration screen displays.