10DualRemote 350 Reference
The DualRemote 350
Pass/Fail: The Pass/Fail indicator turns green when the test passes, or red when the test fails.
Diagnostics
The Diagnostics section of the DualRemote 350 front panel provides more detailed information about failing test results.
WS and DR: Indicate at which end of the tested cable the measurement failed.
•WS lights when a failure occurs at the FrameScope end of the circuit.
•DR lights when a failure occurs at the DualRemote end of the circuit.
•WS and DR both light when failures occur at both ends of the circuit. To determine which failures occurred at which end of the circuit, use the Scroll button.
A column of diagnostic indicators shows details about the cause(s) of a test failure. The failures indicated on the DualRemote 350 are:
Wiremap: Turns red when a fault with the cable connections is detected.
Split Pairs: Turns red when a split pair is detected.
Length/Delay/Skew: Turns red when cable length, signal delay, or skew are outside the passing limits.
NEXT : Turns red when near end
Attenuation: Turns red when attenuation is outside passing limits.
ELFEXT : Turns red when
Return Loss: Turns red when the return signal loss exceeds passing limits.
Other: turns red when any other failing test results occur. If the cable run has multiple test failure causes, the Scroll button scrolls between diagnostic indications. The current selection blinks. The pair indicators and WS or DR indicators associated with the selected failure also blink.
Power
The Power indicator turns green when the DualRemote 350 is powered on.
222 | Agilent FrameScope 350 User’s Manual |