Operation Verification

Table 3-5: SU-ODU LEDs

Name

Description

Functionality

W-LINK

 

Wireless Link

„ Green – Unit is associated with an AU,

 

 

Indictor

no wireless link activity

 

 

 

„ Blinking Green – Data received or

 

 

 

transmitted on the wireless link.

 

 

 

Blinking rate is proportional to wireless

 

 

 

traffic rate

 

 

 

„ Off – Wireless link is disabled

Status

 

Self-test and power

„ Green – Power is available and

 

 

indication

self-test passed.

 

 

 

„ Blinking Amber – Testing (not ready for

 

 

 

operation)

 

 

 

„ Red – Self-test failed – fatal error

ETH

 

Ethernet activity/

„ Green – Ethernet link between the

 

 

connectivity

indoor and outdoor units is detected,

 

 

indication

no activity

 

 

 

 

 

 

„ Blinking Green – Ethernet connectivity

 

 

 

is OK, with traffic on the port. Blinking

 

 

 

rate proportional to traffic rate.

 

 

 

„ Red – No Ethernet connectivity

 

 

 

between the indoor and outdoor units.

SNR BAR

 

Received signal

„ Red LED: Signal is too low

(SU-RA)

 

strength Indication

(SNR<4 dB)

 

 

 

„ 8 green LEDs: Quality of the received

 

 

 

signal

 

 

 

„ Orange LED: Signal is too high

 

 

 

(SNR > 50 dB)

Commissioning