Chapter 4 - Operation and Administration
BreezeACCESS VL System Manual
206
4.2.6.6.4.1 DRAP Support
The DRAP Support option enables or disables the DRAP feature that offers the
possibility of identifying the connected Gateways and limiting the maximum
number of voice calls made by Voice Gateways in a cell.
The default option is Enable.
4.2.6.6.4.2 UDP Port
The UDP Port parameter defines the UDP port used by the DRAP protocol.
The range is from 8000 to 8200.
The default value is 8171.
4.2.6.6.4.3 Maximum Number of Voice Calls
The Maximum Number of Voice Calls parameter sets the maximum number of
active calls in the cell.
The range is between 0 and 255.
The default value is 40.
4.2.6.6.4.4 DRAP TTL
The DRAP TTL parameter sets the time between two consecutive Allocation
Requests from the Gateways. The Allocation requests are used to identify the
existence of an active Gateway. In Voice Gateways they also include information
about the current number of voice calls and requests for new calls.
The range is between 1 and 255 (seconds).
The default value is 10 (seconds).
4.2.6.6.4.5 Number of Active Voice Calls
This option shows the current number of active voice calls in the cell.
4.2.6.6.5 Show Service Parameters
Displays the current values of the Service Parameters.