Chapter 4 - Operation and Administration

The default is 8.

4.2.6.2.19.2.4KeepLink (AU only)

Activates or deactivates the KeepLink feature:

„0 – Disable KeepLink

„1 – Enable KeepLink

The default is 1 (Enabled).

4.2.6.2.19.2.5Channel Scan Period

The period of time, in seconds, the unit will stay on each channel to gather information. The unit may stop recording prematurely if a 100 000 events limit is reached.

The available range is from 2 to 30 minutes.

The default is 5 minutes.

4.2.6.2.19.2.6Automatic Scan Period

The period of time, in minutes, after which the unit will rerun the Interference Mitigation channel scan. Setting this value to 0 will disable periodicity, allowing only one-time manually triggered Interference Mitigation scans.

The available range is 0 (disabled) or 10 - 10080 (minutes)

Default value is 0 (disabled).

4.2.6.2.19.2.7Frequency Subset (AU only)

This setting allows you to select the channels that will be scanned during the Interference Mitigation process. All the defined frequencies and their indexes will be displayed. Frequencies are indexed with consecutive numbers starting from 1. Enter the desired channels’ corresponding indexes separated by commas (for example: 1, 4, 5, 6, 14, 18, 19) or enter A to select all defined frequencies.

4.2.6.2.19.3 Activation

Starts the Interference Mitigation process. Keep in mind that during the scan, the AU will lose connectivity to the associated SUs. A final validation is required prior to the scan:

„0 – Cancel Operation

„1 – Activate Interference Mitigation (Causes Automatic Reset)

BreezeACCESS VL System Manual

160

Page 192
Image 192
Alvarion SW VERSION 5.1 KeepLink AU only, Channel Scan Period, Automatic Scan Period, Frequency Subset AU only, Activation