Chapter 4 - Operation and Administration
The Minimum Contention Window parameter determines the time that a unit waits from the time it has concluded that there are no detectable transmissions by other units until it attempts to transmit. The BreezeACCESS VL system uses a special mechanism based on detecting the presence of a carrier signal and analyzing the information contained in the transmissions of the AU to estimate the activity of other SUs served by the AU. The target is to minimize collisions in the wireless medium resulting from attempts of more than one unit to transmit at the same time.
The system uses an exponential
The Minimum Contention Window parameter is the first maximum number C used in the
The available values are 0, 7, 15, 31, 63, 127, 255, 511 and 1023. A value of 0 means that the contention window algorithm is not used and that the unit will attempt to access the medium immediately after a time equal to DIFS.
The default value is 15.
CAUTION
A value of 0 disables the contention window
4.2.6.5.2Maximum Contention Window
The Maximum Contention Window parameter defines the upper limit for the maximum number C used in the
The available values are 7, 15, 31, 63, 127, 255, 511 and 1023.
The default value is 1023.
BreezeACCESS VL System Manual
184