Chapter 3 - Commissioning

3.1Configuring Basic Parameters

3.1.1Initial Configuration

After completing the installation process, as described in the preceding chapter, the basic parameters must be configured to ensure that the unit operates correctly. After the basic parameters have been configured, additional parameters can be remotely configured via the Ethernet port or the wireless link using Telnet or SNMP management, or by loading a configuration file.

Refer to section 4.1 for information on how to access the Monitor program using Telnet and how to use it.

The Basic Configuration menu includes all the parameters necessary for the initial installation and operation of Subscriber and Access Units. In many installations, most of these parameters should not be changed from their default values. The basic parameters and their default values are listed in Table 3-1.

Refer to Chapter 4 for detailed information on the applicable parameters.

 

Table 3-1: Basic Parameters

 

 

 

 

 

 

Parameter

Default Value

Comment

 

Ethernet Port Negotiation Mode

Auto Negotiation

 

 

(in Unit Control Parameters)

 

 

 

 

 

 

 

IP Address

10.0.0.1

 

 

 

 

 

 

Subnet Mask

255.0.0.0

 

 

 

 

 

 

Default Gateway Address

0.0.0.0

 

 

 

 

 

 

DHCP Options

Disable

 

 

 

 

 

 

Access to DHCP

AU: From Ethernet Only

 

 

 

SU: From Wireless Only

 

 

 

 

 

 

ESSID

ESSID1

 

 

 

 

 

 

Country Code Select

Depends on factory

Applicable only for 5.4

 

 

configuration

and 5.8 GHz units. See

 

 

 

3.1.2 below.

 

 

 

 

 

Sub-Band Select (AU)

1

Applicable only if more

 

 

 

than one Sub-Band is

 

 

 

available

 

 

 

 

 

Frequency (AU)

The lowest frequency in

 

 

 

the selected Sub-Band

 

 

 

 

 

 

 

 

 

70

 

BreezeACCESS VL System Manual

 

 

 