Chapter 3 - Commissioning
BreezeACCESS VL System Manual
70
3.1 Configuring Basic Parameters

3.1.1 Initial Configuration

After completing the installation process, as described in the preceding chapter,
the basic parameters must be configured to ensure that the unit operates
correctly. After the basic parameters have been configured, additional parameters
can be remotely configured via the Ethernet port or the wireless link using Telnet
or SNMP management, or by loading a configuration file.
Refer to section 4.1 for information on how to access the Monitor program using
Telnet and how to use it.
The Basic Configuration menu includes all the parameters necessary for the
initial installation and operation of Subscriber and Access Units. In many
installations, most of these parameters should not be changed from their default
values. The basic parameters and their default values are listed in Table 3-1.
Refer to Chapter 4 for detailed information on the applicable parameters.
Table 3-1: Basic Parameters
Parameter Default Value Comment
Ethernet Port Negotiation Mode
(in Unit Control Parameters)
Auto Negotiation
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Options Disable
Access to DHCP AU: From Ethernet Only
SU: From Wireless Only
ESSID ESSID1
Country Code Select Depends on factory
configuration
Applicable only for 5.4
and 5.8 GHz units. See
3.1.2 below.
Sub-Band Select (AU) 1 Applicable only if more
than one Sub-Band is
available
Frequency (AU) The lowest frequency in
the selected Sub-Band