Appendix E - Parameters Summary

E.1 Parameters Summary

E.1.1 Unit Control Parameters

Parameter

Unit

 

Range

 

Change Unit Name

AU, SU

Up to 32 printable ASCII characters

 

Change Read Only

AU, SU

Up to 8 printable ASCII characters

 

Password

 

 

 

 

Change Installer

AU, SU

Up to 8 printable ASCII characters

 

Password

 

 

 

 

Change Administrator

AU, SU

Up to 8 printable ASCII characters

 

Password

 

 

 

 

FTP SW Version File

AU, SU

Up to 20 printable ASCII characters.

 

Name

 

An empty string is not allowed.

 

Configuration File Name

AU, SU

Up to 20 printable ASCII characters.

 

 

 

An empty string is not allowed.

 

Operator Defaults File

AU, SU

Up to 20 printable ASCII characters.

 

Name

 

An empty string is not allowed.

 

FTP Source Dir

AU, SU

Up to 80 printable ASCII characters.

 

 

 

Use “.” to clear.

 

FTP Server IP Address

AU, SU

IP address

 

FTP Gateway IP Address

AU, SU

IP address

 

FTP User Name

AU, SU

Up to 18 printable ASCII characters

 

FTP Password

AU, SU

Up to 18 printable ASCII characters

 

FTP Log File Name

AU, SU

Up to 20 printable ASCII characters

 

FTP Log File Destination

AU, SU

Up to 80 printable ASCII characters.

 

Directory

 

Use “.” to clear.

 

Event Log Policy

AU, SU

„

Message

 

 

 

„

Warning

 

 

 

„

Error

 

 

 

„

Fatal

 

 

 

„

Log None

 

 

 

 

 

Log Out Timer

AU, SU

1-999 minutes

 

 

 

 

 

Ethernet Port Negotiation

AU, SU

„ Force 10 Mbps and Half-Duplex

 

Mode

 

„ Force 10 Mbps and Full-Duplex

 

 

 

 

 

 

„ Force 100 Mbps and Half-Duplex

 

 

 

„ Force 100 Mbps and Full-Duplex

 

 

 

„

Auto Negotiation

 

 

 

 

 

Change System Location

AU, SU

Up to 34 printable ASCII characters

 

Manual Feature Upgrade

AU, SU

License string: 32 to 64 hexadecimal

 

 

 

digits

 

 

 

 

 

 

Default

None public

user

private

VxWorks.bz

config.cfg

operator.cmr

None (empty)

10.0.0.253

0.0.0.0 vx

vx logfile.log None (empty)

Warning

5

Auto Negotiation

None

None

Run-Time

Yes

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

No

BreezeACCESS VL System Manual

226

Page 258
Image 258