Chapter 2 - Installation

2.4Installing the Universal IDU Indoor Unit

The unit can be placed on a desktop or a shelf. Alternatively, it may be wall-mounted using the kit supplied with the unit.

Figure 2-13: IDU PS 1073 Front Panel

The RADIO connector and RESET button are located on the front panel, the ETHERNET connector is located on the side panel and LEDs are located on the top panel.

CAUTION

Do not connect the data equipment to the RADIO port. The RADIO port supplies DC power to the ODU, and this may harm other equipment connected to it.

To install the IDU:

1Connect the Indoor-to-Outdoor cable to the RADIO connector, located on the front panel of the indoor unit.

2Connect the power cord to the unit's AC socket, located on the rear panel. Connect the other end of the power cord to the AC mains. The unit can operate with AC mains of 100-240 VAC, 50-60 Hz.

NOTE

The color codes of the power cable are as follows:

Brown

Phase

~

Blue

Neutral

0

Yellow/Green

Ground

 

3Verify that the POWER LED is lit, indicating that power is supplied to the unit.

4Configure the basic parameters as described in section 3.1.

5Connect the 10/100 BaseT ETHERNET connector to the network. The cable connection should be a straight Ethernet if connecting the indoor unit to a hub/switch and a crossed cable if connecting it directly to a PC Network Interface Card (NIC).

52

BreezeACCESS VL System Manual

Page 84
Image 84
Alvarion SW VERSION 5.1 system manual Installing the Universal IDU Indoor Unit, To install the IDU