7-21
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter7 Configuring Virtual Connections
Configuring SoftPVC Connections
Note The row index for rx-cttr and tx-cttr must be configured before using this optional parameter. See
Chapter 9, “Configuring Resource Management.”
Examples
The following example shows the destination ATM address of the interface connected to UserD:
Switch-C# show atm addresses
Switch Address(es):
47.00918100000000400B0A2A81.00400B0A2A81.00 active
47.00918100000000E04FACB401.00E04FACB401.00
Soft VC Address(es):
<Information deleted>
47.0091.8100.0000.00e0.4fac.b401.4000.0c80.9000.00 ATM1/1/0
47.0091.8100.0000.00e0.4fac.b401.4000.0c80.9010.00 ATM1/1/1
47.0091.8100.0000.00e0.4fac.b401.4000.0c80.9020.00 ATM1/1/2
<Information deleted>
The following example shows how to configure a soft PVC on Switch B between interface ATM 0/0/2,
source VPI = 0, VCI = 1000; and Switch C, destination VPI = 0, VCI = 1000 with a specified
ATMaddress (see Figu re 7-6):
Switch-B(config)# interface atm 0/0/2
Switch-B(config-if)# atm soft-vc 0 1000 dest-address
47.0091.8100.0000.00e0.4fac.b401.4000.0c80.9010.00 0 1000
Step3 Switch(config)# interface atm
card/subcard/port[.vpt#]
Switch(config-if)#
Selects the interface to be configured.
Step4 Switch(config-if)# atm soft-vc source-vpi
source-vci dest-address atm-address dest-vpi
dest-vci [enable | disable] [upc upc] [pd pd]
[rx-cttr index] [tx-cttr index]
[retry-interval [first interval]
[maximum interval]] [redo-explicit
[explicit-path precedence {name path-name |
identifier path-id} [upto partial-entry-index]]
[only-explicit]] [hold-priority priority]
[timer-group name]
Configures the soft PVC connection.
Command Purpose