3-27
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter3 Initially Configuring the ATMSw itch Router
Testing the Configuration

Example (Catalyst8510 MSR an d LightStream 1010)

The following example displays the power-on diagnostic tests results for the Catalyst8510 MSR and LightStream 1010:
NewLs1010# show diag power-on
LS1010 Power-on Diagnostics Status (.=Pass,F=Fail,U=Unknown,N=Not Applicable)
-----------------------------------------------------------------------------
Last Power-on Diags Date: 99/07/09 Time: 07:52:17 By: V 4.51
BOOTFLASH: . PCMCIA-Slot0: . PCMCIA-Slot1: N
CPU-IDPROM: . FCard-IDPROM: . NVRAM-Config: .
SRAM: . DRAM: .
PS1: . PS2: N PS (12V): .
FAN: . Temperature: . Bkp-IDPROM: .
MMC-Switch Access: . Accordian Access: .
LUT: . ITT: . OPT: . OTT: . STK: . LNK: . ATTR: . Queue: .
Cell-Memory: .
FC-PFQ
Access: .
RST: . REG: . IVC: . IFILL: . OVC: . OFILL: .
TEST:
CELL: . SNAKE: . RATE: . MCAST: . SCHED: .
TGRP: . UPC : . ABR : . RSTQ : .
Access/Interrupt/Loopback/CPU-MCast/Port-MCast/FC-MCast/FC-TMCC Test Status:
Ports 0 1 2 3
----------------------------------------------------------------------------
PAM 0/0 (IMA8T1) .....NN .....NN .....NN .....NN
Port 4 to 7 : .....NN .....NN .....NN .....NN
PAM 0/1 (IMA8E1) .....NN .....NN .....NN .....NN
Port 4 to 7 : .....NN .....NN .....NN .....NN
PAM 1/0 (FR4CE1) .....NN .....NN .....NN .....NN
PAM 1/1 (155UTP) .....NN .....NN .....NN .....NN
PAM 3/0 (T1) .....NN .....NN .....NN .....NN
PAM 3/1 (E1CEUTP) .....NN .....NN .....NN .....NN
PAM 4/0 (DS3) .....NN .....NN N N
PAM 4/1 (25M) .....NN .....NN .....NN .....NN
Port 4 to 7 : .....NN .....NN .....NN .....NN
Port 8 to 11: .....NN .....NN .....NN .....NN
FRPAM# ING-SSRAM ING-SDRAM EGR-SSRAM EGR-SDRAM LOOPBACK
------------------------------------------------------------------
PAM 1/0 (FR4CE1) . . . . .
Ethernet-port Access: . Ethernet-port CAM-Access: .
Ethernet-port Loopback: . Ethernet-port Loadgen: .
GEPAM Microcode: . GEPAM Access: .
GEPAM CAM Access: .
Power-on Diagnostics Passed.