20-9
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter20 Configuring Frame Relay to ATM Interworking Port Adapter Interfaces
Configuring Frame Relay to ATM Interworking Functions

Displaying the CE1 Frame Relay Port Adapter Controller Information

To display your controller configuration, use the following EXEC command:
Example
The configuration for controller E1 is displayed in the following example:
Switch# show controllers e1 0/0/0 tabular
E1 0/0/0 is up.
E1 0/0/0 is up.
PAM state is Up
4CE1 H/W Version: 3.1
4CE1 F/W Version: 2.0
No alarms detected.
Framing is crc4, Line Code is HDB3, Clock Source is line.
INTERVAL LCV PCV CS SELS LES DM ES BES SES UAS SS
18:38-18:51 0 0 0 0 0 0 2 0 10 704 0
Configuring Frame Relay to ATM Interworking Functions
You must follow the required steps to enable Frame Relay to ATM interworking on your ATM switch
router. In addition, you can customize Frame Relay to ATM for your particular network needs and
monitor Frame Relay to ATM connections. The following sections outline these tasks:
Enabling Frame Relay Encapsulation on an Interface, page 20-9
Configuring Frame Relay Serial Interface Type, page 20-10
For information on how to customize your Frame Relay to ATM connections, see Configuring LMI, page
20-14 and Configuring Frame Relay to ATM Resource Management, page 20-18.

Enabling Frame Relay Encapsulation on an Interface

To set Frame Relay encapsulation on the serial interface, perform the following steps, beginning in
global configuration mode:
Frame Relay supports encapsulation of all supported protocols in conformance with RFC 1490, allowing
interoperability between multiple vendors.
Command Purpose
show controllers e1 card/subcard/port [brief
| tabular]
Displays E1 controller configuration.
Command Purpose
Step1 Switch(config)# interface serial
card/subcard/port:cgn
Switch(config-if)#
Selects the interface to be configured.
Step2 Switch(config-if)# encapsulation frame-relay
ietf
Configures Frame Relay encapsulation.