Viewing the System Event Log

Procedure

 

Command or Action

Purpose

Step 1

Server# scope sel

Enters the system event log (SEL) command mode.

Step 2

Server /sel # show entries

For system events, displays timestamp, the severity of the

 

[detail]

event, and a description of the event. The detail keyword

 

 

displays the information in a list format instead of a table

 

 

format.

This example displays the system event log:

Server# scope

sel

 

 

Server /sel #

show entries

Description

Time

 

Severity

-------------------

------------- ----------------------------------------

[System Boot]

 

Informational " LED_PSU_STATUS: Platform sensor, OFF event was asserted"

[System Boot]

 

Informational " LED_HLTH_STATUS: Platform sensor, GREEN was asserted"

[System Boot]

 

Normal

" PSU_REDUNDANCY: PS Redundancy sensor, Fully Redundant

was asserted"

 

Normal

" PSU2 PSU2_STATUS: Power Supply sensor for PSU2, Power

[System Boot]

 

Supply input lost (AC/DC) was deasserted"

[System Boot]

 

Informational " LED_PSU_STATUS: Platform sensor, ON event was asserted"

[System Boot]

 

Informational " LED_HLTH_STATUS: Platform sensor, AMBER was asserted"

[System Boot]

 

Critical

" PSU_REDUNDANCY: PS Redundancy sensor, Redundancy Lost

was asserted"

 

Critical

" PSU2 PSU2_STATUS: Power Supply sensor for PSU2, Power

[System Boot]

 

Supply input lost (AC/DC) was asserted"

[System Boot]

 

Normal

" HDD_01_STATUS: Drive Slot sensor, Drive Presence was

asserted"

 

Critical

" HDD_01_STATUS: Drive Slot sensor, Drive Presence was

[System Boot]

 

deasserted"

 

Informational " DDR3_P2_D1_INFO: Memory sensor, OFF event was asserted"

[System Boot]

 

2001-01-01 08:30:16

Warning

" PSU2 PSU2_VOUT: Voltage sensor for PSU2, failure event

was deasserted"

 

" PSU2 PSU2_VOUT: Voltage sensor for PSU2, non-recoverable

2001-01-01 08:30:16 Critical

event was deasserted"

 

2001-01-01 08:30:15 Informational " LED_PSU_STATUS: Platform sensor, ON event was asserted"

2001-01-01 08:30:15 Informational " LED_HLTH_STATUS: Platform sensor, AMBER was asserted"

2001-01-01 08:30:15 Informational " LED_HLTH_STATUS: Platform sensor, FAST BLINK event was asserted"

2001-01-01 08:30:14 Non-Recoverable " PSU2 PSU2_VOUT: Voltage sensor for PSU2, non-recoverable

event was

asserted"

" PSU2 PSU2_VOUT: Voltage sensor for PSU2, failure event

2001-01-01

08:30:14 Critical

was asserted"

 

--More--

 

 

 