Cisco Systems 57712 Trust-host-cos disable enable, Vlan-mode access trunk, Channel-number number

Models: 57712 UCSCPCIEBTG

1 288
Download 288 pages 20.54 Kb
Page 117
Image 117

Managing Network Adapters

Modifying vNIC Properties

 

Command or Action

Purpose

 

 

Note

If NIV is enabled, this setting is determined

 

 

 

by the switch, and the command is ignored.

Step 9

Server /chassis/adapter/host-eth-if # set

Specifies whether the vNIC will trust host CoS or will

 

trust-host-cos {disable enable}

remark packets. The behavior is as follows:

 

 

disable Received packets are remarked with

 

 

 

the configured CoS. This is the default.

 

 

enable The existing CoS value of received

 

 

 

packets (host CoS) is preserved.

Step 10

Server /chassis/adapter/host-eth-if # set

Specifies the relative order of this device for PCI bus

 

order {any 0-99}

device number assignment; the default is any.

Step 11

Server /chassis/adapter/host-eth-if # set

Specifies the default VLAN for this vNIC. Valid VLAN

 

vlan {none vlan-id}

numbers are 1 to 4094; the default is none.

 

 

Note

If NIV is enabled, this setting is determined

 

 

 

by the switch, and the command is ignored.

Step 12

Server /chassis/adapter/host-eth-if # set

Specifies the VLAN mode for the vNIC. The modes

 

vlan-mode {access trunk}

are as follows:

 

 

access The vNIC belongs to only one VLAN.

 

 

trunk The vNIC can belong to more than one

 

 

 

VLAN. This is the default.

 

 

Note

If NIV is enabled, this setting is determined

 

 

 

by the switch, and the command is ignored.

Step 13

Server /chassis/adapter/host-eth-if # set

Specifies a maximum data rate for the vNIC. The range

 

rate-limit {off rate}

is 1 to 10000 Mbps; the default is off.

 

 

Note

If NIV is enabled, this setting is determined

 

 

 

by the switch, and the command is ignored.

Step 14

Server /chassis/adapter/host-eth-if # set

Specifies whether the vNIC can be used to perform a

 

boot {disable enable}

PXE boot. The default is enable for the two default

 

 

vNICs, and disable for user-created vNICs.

Step 15

Server /chassis/adapter/host-eth-if # set

If NIV mode is enabled for the adapter, select the

 

channel-number number

channel number that will be assigned to this vNIC. The

 

 

range is 1 to 1000.

Step 16

Server /chassis/adapter/host-eth-if # set

If NIV mode is enabled for the adapter, select the port

 

port-profile name

profile that should be associated with the vNIC.

 

 

Note

The name must be a port profile defined on

 

 

 

the switch to which this server is connected.

Step 17

Server /chassis/adapter/host-eth-if # set

If NIV mode is enabled for the adapter, enable this

 

uplink-failover {disable enable}

setting if traffic on this vNIC should fail over to the

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

OL-28893-01

101

Page 117
Image 117
Cisco Systems 57712 manual Trust-host-cos disable enable, Vlan-mode access trunk, Channel-number number, Port-profile name