CIMC Firmware Management

Activating Installed CIMC Firmware

Important While the activation is in progress, do not:

Reset, power off, or shut down the server.

Reboot or reset CIMC.

Activate any other firmware.

Export technical support or configuration data.

Procedure

 

Command or Action

Purpose

Step 1

Server# scope cimc

Enters the CIMC command mode.

Step 2

Server /cimc # scope firmware

Enters the firmware command mode.

Step 3

Server /cimc/firmware # show detail

Displays the available firmware images and

 

 

status.

Step 4

Server /cimc/firmware # activate [1 2]

Activates the selected image. If no image number

 

 

is specified, the server activates the currently

 

 

inactive image.

Step 5

At the prompt, enter y to activate the

The BMC reboots, terminating all CLI and GUI

 

selected firmware image.

sessions until the reboot completes.

Step 6

Log back into the CLI and repeat steps 13

(Optional)

 

to verify the activation.

 

This example activates firmware image 1 and then verifies the activation after the BMC reboots:

Server# scope cimc

Server /cimc # scope firmware

Server /cimc/firmware # show detail

Firmware Image Information:

Update Stage: NONE

Update Progress: 100

Current FW Version: 1.3(3a)

FW Image 1 Version: 1.4(3j)

FW Image 1 State: BACKUP INACTIVATED

FW Image 2 Version: 1.3(3a)

FW Image 2 State: RUNNING ACTIVATED

Boot-loader Version: 1.4(3.21).18

Server /cimc/firmware # activate 1

This operation will activate firmware 1 and reboot the BMC. Continue?[yN]y

.

.

-- BMC reboot --

.

.

-- Log into CLI as Admin --

Server# scope cimc

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

OL-28893-01

161

Page 177
Image 177
Cisco Systems 57712 Server /cimc/firmware # activate 1, Is specified, the server activates the currently, Inactive image