Viewing Server Sensors

Viewing Fan Sensors

PSU2_STATUS

Normal

present

Server /sensor # show psu-redundancy

Name

Reading

Sensor Status

--------------------

----------

--------------------

PSU_REDUNDANCY

full

Normal

Server /sensor #

Viewing Fan Sensors

Procedure

 

Command or Action

 

 

Purpose

 

Step 1

Server# scope sensor

 

 

Enters sensor command mode.

Step 2

Server /sensor # show fan [detail]

 

Displays fan sensor statistics for the server.

This example displays fan sensor statistics:

 

 

 

 

Server# scope sensor

 

 

 

 

Server /sensor # show fan

Reading

Units

Min. Warning

Max. Warning

Name

Sensor Status

Min. Failure

Max. Failure

 

---------- --------------- ---------------

-------------------- -------------- ----------

--------------- ---------------

2400

RPM

N/A

N/A

W793_FAN2_TACH1

Normal

800

N/A

2400

RPM

N/A

N/A

W793_FAN2_TACH2

Normal

800

N/A

2300

RPM

N/A

N/A

W793_FAN3_TACH1

Normal

800

N/A

2300

RPM

N/A

N/A

W793_FAN3_TACH2

Normal

800

N/A

2400

RPM

N/A

N/A

W793_FAN4_TACH1

Normal

800

N/A

1600

RPM

N/A

N/A

W793_FAN4_TACH2

Normal

800N/A

Server /sensor #

Viewing Temperature Sensors

Procedure

 

Command or Action

Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show temperature [detail]

Displays temperature sensor statistics for the

 

 

server.

 

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

50

OL-28893-01

Page 66
Image 66
Cisco Systems UCSCPCIEBTG manual Viewing Fan Sensors, Viewing Temperature Sensors, Server /sensor # show temperature detail