PSU2_STATUS Normal present
Server /sensor # show psu-redundancy
Name Reading Sensor Status
-------------------- ---------- --------------------
PSU_REDUNDANCY full Normal
Server /sensor #
Viewing Fan Sensors
Procedure
PurposeCommand or Action
Enterssensor command mode.Server# scopesensor
Step 1
Displaysfan sensorstatistics for theserver.Server/sensor # showfan [detail]
Step 2
Thisexample displays fan sensorstatistics:
Server# scope sensor
Server /sensor # show fan
Name Sensor Status Reading Units Min. Warning Max. Warning
Min. Failure Max. Failure
-------------------- -------------- ---------- ---------- --------------- ---------------
--------------- ---------------
W793_FAN2_TACH1 Normal 2400 RPM N/A N/A
800 N/A
W793_FAN2_TACH2 Normal 2400 RPM N/A N/A
800 N/A
W793_FAN3_TACH1 Normal 2300 RPM N/A N/A
800 N/A
W793_FAN3_TACH2 Normal 2300 RPM N/A N/A
800 N/A
W793_FAN4_TACH1 Normal 2400 RPM N/A N/A
800 N/A
W793_FAN4_TACH2 Normal 1600 RPM N/A N/A
800 N/A
Server /sensor #
Viewing Temperature Sensors
Procedure
PurposeCommand or Action
Enterssensor command mode.Server# scope sensor
Step 1
Displaystemperature sensor statisticsfor the
server.
Server/sensor # show temperature [detail]
Step 2
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
50 OL-28893-01
Viewing Server Sensors