Americas Headquarters
First Published March 04
Page
 N T E N T S
 Viewing Server Properties
 Viewing Server Sensors
 Managing User Accounts
 Creating a vNIC
 Configuring Communication Services
 Configuring Platform Event Filters
 Bios Parameters by Server Model
 Preface
Audience
Conventions
This preface includes the following sections
 Default responses to system prompts are in square brackets
String
String will include the quotation marks
Indicates a comment line
 Feature Description Where Documented
New and Changed Information for this Release
 Feature Description
 Related Cisco UCS Documentation
Documentation Roadmaps
 Other Documentation Resources
System UCS Documentation Roadmap Bundle
 This chapter includes the following sections
Overview
Overview of the Server Software
 Cisco Integrated Management Controller
Cimc Firmware
Server OS
Management Interfaces
 Command Modes
Cimc CLI
 Overview Command Modes
 Mode Name
Command to Access Mode Prompt
 Command to Access Mode Prompt
 Scope role-group command from
Scope power-cap command from
Scope sensor command from
Scope trap-destinations command
 Complete a Command
Command History
Committing, Discarding, and Viewing Pending Commands
Command Output Formats
 Online Help for the CLI
 OL-28893-01
 KVM Console
Installing the Server OS
OS Installation Methods
 You can use the KVM console to install an OS on the server
PXE Installation Servers
Installing an OS Using a PXE Installation Server
 Command or Action Purpose Step
Enters chassis command mode
Managing the Server
Toggling the Locator LED
 Managing the Server Boot Order
Server Boot Order
Toggling the Locator LED for a Hard Drive
Server /chassis/hdd # set locateHDD
 Configuring the Server Boot Order
Server# scope bios
 Resetting the Server
Viewing the Actual Server Boot Order
Server /bios # show actual-boot-order
Detail
 Server# scope chassis Enters chassis mode
Server /chassis # power shutdown
Shutting Down the Server
Server# scope chassis
 Powering Off the Server
Managing Server Power
Powering On the Server
 Server# scope chassis Enters chassis command mode
Power Cycling the Server
Command or Action Purpose
 Name Description
Configuring Power Policies
Viewing the Power Statistics
 Non-Compliance Action
Power Capping Policy
Configuring the Power Cap Policy
 Server# scope power-cap
Enters the power cap command mode
Server /power-cap # set
Enabled yes no
 Configuring the Power Restore Policy
Power-off power-on
Restore-last-state
Delay-value delay
 Managing the Flexible Flash Controller
Cisco Flexible Flash
Dual Card Management in the Cisco Flexible Flash Controller
Action Description
 Configuring the Flexible Flash Controller Properties
Scenario Behavior
 # set read-error-count-threshold
# set write-error-count-threshold
# set virtual-drives-enabled list
# set raid-primary-member slot1
 None SCU HV HUU
Booting from the Flexible Flash
Server /bios # set boot-override
 Resetting the Flexible Flash Controller
Permissible index value is FlexFlash-0
 Default configuration
Server /chassis/flexflash # commit
 Configuring Bios Settings
Viewing Bios Status
Bios Version Version string of the running Bios
Secondary slot
 Configuring Main Bios Settings
Boot Order
For each Bios setting, see one the following topics
Attempt to use
 Configuring Advanced Bios Settings
On, you are prompted to choose whether to reboot now
Configure the Bios settings Server /bios/advanced #
Server /bios/main # set POSTErrorPause Enabled
 Configuring Server Management Bios Settings
Command or Action
Configure the Bios settings
Server-management
 Server /bios # bios-setup-default
Restoring Bios Defaults
Restoring Bios Manufacturing Custom Defaults
 Server # scope bios Server /bios # restore-mfg-defaults
Server /bios # restore-mfg-defaults
Default values
 OL-28893-01
 Viewing Server Properties
Viewing Server Properties
Server# show chassis detail
Displays server properties
 Viewing Cimc Properties
Viewing CPU Properties
Server# show cimc detail
Displays Cimc properties
 Viewing Memory Properties
This example displays Dimm summary information
 Viewing Power Supply Properties
Viewing Storage Properties
Viewing Storage Adapter Properties
Show psu detail
 Error-counters detail
Hw-config detail
Settings detail
Server /chassis # show storageadapter
 Viewing the Flexible Flash Controller Properties
Server /chassis # show flexflash detail
Optional Displays the available Cisco Flexible
Flash controllers
 Viewing Physical Drive Properties
 Viewing Virtual Drive Properties
Virtual-drive drive-number detail
Virtual-drive-count detail
Virtual-drive drive-number
 Server # scope chassis
Viewing Nvidia GPU Card Information
Slot number of the GPU card
 Viewing PCI Adapter Properties
Viewing Network Related Properties
Viewing LOM Properties
Server# scope cimc
 Server# scope cimc Network
 OL-28893-01
 Viewing Power Supply Sensors
Viewing Server Sensors
Server# scope sensor
Show psu-redundancy
 Viewing Temperature Sensors
Server /sensor # show temperature detail
Viewing Fan Sensors
Server /sensor # show psu-redundancy
 Purpose Step
This example displays temperature sensor statistics
Viewing Voltage Sensors
 Procedure Command or Action Purpose Step
Viewing Current Sensors
Viewing Storage Sensors
Status column
 LED Status column
Current LED color, if any
 OL-28893-01
 KVM Console
Managing Remote Presence
Managing the Virtual KVM
 Server /kvm # set enabled yes
Enabling the Virtual KVM
Disabling the Virtual KVM
Server# scope kvm
 Configuring the Virtual KVM
Set encrypted yes
Set local-video yes
Server /kvm # set max-sessions
 Server# scope vmedia
Configuring Virtual Media
Set enabled yes
 Configuring Network Mounted vMedia Mapping
Command or Action Server # scope vmedia
Volume-name remote-share
Remote-file-path mount options
 Enters the virtual media command mode
Viewing Network Mount vMedia Mapping Properties
Removing Network Mounted vMedia Mapping
Server # scope vmedia
 Managing Serial over LAN
Serial Over LAN
 Configuring Serial Over LAN
Enters SoL command mode
Server# scope sol
Yes no
 Server console port. You can enter this command in any
Command mode
Launching Serial Over LAN
Server# connect host
 OL-28893-01
 Configuring Local Users
Managing User Accounts
 Active Directory
Configuring Active Directory
Configuring the Active Directory Server
 Properties Value
Role
 Configuring Active Directory in Cimc
Server# scope ldap
 Server /ldap *# set dc1 Server /ldap *# set gc1
Configuring Active Directory Groups in Cimc
Server# scope ldap
 Scope role-group
Admin user readonly
Set group-auth
 Viewing User Sessions
Terminating a User Session
 Terminate
 Configuring Network-Related Settings
Server NIC Configuration
NIC Mode
Server NICs
 Configuring Server NICs
Server /cimc/network # set mode dedicated
NIC Redundancy
Sharedlom Sharedlom10g shipping ciscocard
 Configuring Common Properties
Redundancy none
Active-active
Active-standby
 Configuring IPv4
 Configuring the Server Vlan
Optional Displays the IPv4 network settings
You must be logged in as admin to configure the server Vlan
Specifies the IP address of the secondary DNS
 Set vlan-priority
Connecting to a Port Profile
Set vlan-enabled
 Port profile must be defined on the switch to
Displays the network settings
Management interface, the virtual Ethernet, and the VIF on
Supported adapter cards such as the Cisco UCS VIC1225
 Network Security
Network Security Configuration
Configuring Network Security
 Network Time Protocol Configuration
Configuring Network Time Protocol Settings
Server # scope cimc
Yes
 Server /cimc/network/ntp* # commit Commits the transaction
10.120.33.44
10.120.34.45
10.120.35.46
 Managing Network Adapters
Overview of the Cisco UCS C-Series Network Adapters
 Cisco UCS P81E Virtual Interface Card
Cisco UCS VIC1225 Virtual Interface Card
 Index detail
Configuring Network Adapter Properties
Viewing Network Adapter Properties
 Fip-mode disable enable
Niv-mode disable enable
Configure-vmfex port-count
Managing vHBAs
 All vHBAs
Viewing vHBA Properties
Host-fc-if fc0 fc1 name detail
 Modifying vHBA Properties
 Error-detect-timeout msec
Resource-allocation-timeout msec
Error-recovery
# set fcp-error-recovery disable Enable
 Enters the interrupt command mode
Set flogi-timeout msec
Interrupt
Interrupt-mode intx msi msix
 Enters the Fibre Channel port login command mode
Set plogi-timeout msec
Port-p-logi
Server
 Creating a vHBA
Host-fc-if name
 Deleting a vHBA
Set channel-number number
Server /chassis/adapter # delete
Server /chassis/adapter # commit
 VHBA Boot Table
Viewing the Boot Table
Creating a Boot Table Entry
Show boot
 Server /chassis # scope adapter
Deleting a Boot Table Entry
Create-boot-entry wwpn lun-id
 Delete boot entry
Take effect upon the next server reset
VHBA Persistent Binding
Locate the number of the entry to be deleted
 Set persistent-lun-binding enable
Enabling Persistent Binding
Disabling Persistent Binding
Perbi
 Set persistent-lun-binding disable
Rebuilding Persistent Binding
Scope perbi
# rebuild
 Managing vNICs
Guidelines for Managing vNICs
Viewing vNIC Properties
Host-eth-if eth0 eth1 name detail
 Uplink 0
Modifying vNIC Properties
Host-eth-if eth0 eth1 name
 Trust-host-cos disable enable
Vlan-mode access trunk
Uplink-failover disable enable
Channel-number number
 Uplink-failback-timeout seconds
Scope interrupt
Set interrupt-count count
Set coalescing-time usec
 Set tcp-segment-offload disable
# set rq-count count
# set rq-ring-size size
Scope trans-queue
 Set tcp-rx-checksum-offload disable
Set tcp-tx-checksum-offload disable
Set tcp-large-receive-offload disable
Set rss disable enable
 Set rss-hash-tcp-ipv6 disable
Set rss-hash-ipv6-ex disable enable
Set rss-hash-tcp-ipv6-ex disable
Creating a vNIC
 Deleting a vNIC
Host-eth-if name
 Configuring iSCSI Boot Capability
Reboot
You can configure a maximum of 2 iSCSI vNICs for each host
This example deletes a vNIC on adapter
 Iscsi-boot index
Dhcp-net-settings enabled
Dhcp-iscsi-settings enabled
Eth0 eth1 name
 Virtual Machine Fabric Extender
Delete iscsi-boot
Managing VM FEX
 Viewing VM FEX Properties
 Name
VM FEX Settings
General Properties Settings Name Description
 Ethernet Interrupt Settings Name Description
 Completion Queue Settings Name Description
 TCP Offload Settings Name Description
Receive Side Scaling Settings Name
 Managing Storage Adapters
Create Virtual Drive from Unused Physical Drives
Storageadapter slot
Create virtual-drive
 Create Virtual Drive from an Existing Drive Group
Carve-virtual-drive
Write policy for the new virtual drive. Enter
Appropriate information at each prompt
 500 MB
Clearing Foreign Configuration
Server /chassis # scope storageadapter
 # delete-virtual-drive
Clear-foreign-config
Deleting a Virtual Drive
 Cancel-initialization
Initializing a Virtual Drive
Start-initialization
# get-operation-status
 Set as Boot Drive
Set-boot-drive
Modifying Attributes of a Virtual Drive
Server /chassis/storageadapter # scope
 Making a Dedicated Hot Spare
Modify-attributes
Policy
You are prompted to choose a virtual drive for
 Making a Global Hot Spare
Preparing a Drive for Removal
Server /chassis/storageadapter/physical-drive #
Make-global-hot-spare
 # remove-hot-spare
Removing a Drive from Hot Spare Pools
Prepare-for-removal
 Enabling Auto Learn Cycles for the Battery Backup Unit
Enable-auto-learn
Undo Preparing a Drive for Removal
Undo-prepare-for-removal
 Disabling Auto Learn Cycles for the Battery Backup Unit
Starting a Learn Cycle for a Battery Backup Unit
Disable-auto-learn
You must be logged in as an admin to use this command
 Toggling the Locator LED for a Physical Drive
Start-learn-cycle
Physical-drive
# locator-led on off
 Viewing Storage Controller Logs
Backing Up and Restoring the Adapter Configuration
Exporting the Adapter Configuration
 Importing the Adapter Configuration
This example exports the configuration of adapter
 Restoring Adapter Defaults
Reboot the server to apply the imported configuration
Adapter-reset-defaults index
PCI slot number specified by the index
 Installing Adapter Firmware
Managing Adapter Firmware
Adapter Firmware
Or two specified adapters or, if no adapter is specified
 Server /chassis # activate-adapter-fw
Resetting the Adapter
Activating Adapter Firmware
 Server/chassis # adapter-reset index
Resetting the adapter also resets
This example resets the adapter in PCI slot
Host
 Configuring Communication Services
Configuring Http
Server# scope http
Server /http # set http-redirect yes
 Configuring SSH
Set timeout seconds
Server# scope ssh
Set ssh-port number
 Configuring XML API
XML API for Cimc
Enabling XML API
Server# scope xmlapi
 Configuring Ipmi
Configuring Ipmi over LAN
Set enabled
Ipmi Over LAN
 Configuring Snmp
Configuring Snmp Properties
Encryption-key key
Server# scope snmp
 Setcommunity-access
Community-str community
Settrap-community-str
Server /snmp # set sys-location
 Configuring Snmp Trap Settings
Trap-destinations number
Version 1 2
Type trap inform
 Configuring SNMPv3 Users
Sending a Test Snmp Trap Message
To send a test message
Specified user number
 V3security-name security-name
V3security-level noauthnopriv
Authnopriv authpriv
MD5 SHA
 142
 Generating a Certificate Signing Request
Managing Certificates
Managing the Server Certificate
 Enters the certificate command mode
Server# scope certificate
Server /certificate # generate-csr
Signing request CSR
 Creating a Self-Signed Certificate
Managing Certificates Creating a Self-Signed Certificate
 Openssl genrsa -out CAkeyfilename
Example
Openssl req -new -x509 -days numdays
Echo nsCertType = server openssl.conf
 New server certificate
Uploading a Server Certificate
Server /certificate # upload
 This example uploads a new certificate to the server
Begin Certificate
 Configuring Platform Event Filters
Server# scope fault
Platform-event-enabled yes
Platform Event Filters
 Disabling Platform Event Alerts
Configuring Platform Event Filters
Platform-event-enabled no
 Platform Event Filter
None reboot power-cycle
Power-off
 Enabled yes
Configuring Platform Event Trap Settings
Server /fault # scope pef-destinations
 Interpreting Platform Event Traps
Platform Event Trap Descriptions
Event Number Note Platform Event Description
Test Trap
 154
 Event Number Note
155
 156
 Cimc Firmware Management
Overview of Firmware
 Obtaining Firmware from Cisco
Center box, click Unified Computing and Servers
Click the Unified Computing System UCS Server Firmware link
Click Accept License Agreement
 Installing Cimc Firmware from a Remote Server
Log in to the as a user with admin privileges
 Activating Installed Cimc Firmware
 Inactive image
Server /cimc/firmware # activate 1
Is specified, the server activates the currently
 Installing Bios Firmware from a Remote Server
Current FW Version field
 Server # scope bios
163
 164
 Viewing the Faults and Logs Summary
Scope fault
Show fault-entries
Viewing Logs
 Cimc Log
Viewing the Cimc Log
 Configuring the Cimc Log Threshold
Clearing the Cimc Log
Server /cimc # scope log
Server /cimc/log # clear
 Remote-syslog-severity level
Sending the Cimc Log to a Remote Server
Local-syslog-severity
 Server-ip ip-address
Error Informational Debug
Critical
 Server# scope sel
System Event Log
Viewing the System Event Log
 Server# scope sel
Enters the system event log command mode
Clearing the System Event Log
 172
 Server Utilities
Exporting Technical Support Data
Server /cimc # scope tech-support
Remote-ip ip-address
 Remote-username name
Remote-password password
Remote-protocol protocol
 Rebooting the Cimc
Clearing the Bios Cmos
Server# scope bios Enters the bios command mode
Provide the generated report file to Cisco TAC
 Recover
Recovering from a Corrupted Bios
Scope bios
 Power cycle or reset the server
Resetting the Cimc to Factory Defaults
This example shows how to recover from a corrupted Bios
 Exporting and Importing the Cimc Configuration
Exporting and Importing the Cimc Configuration
Exporting the Cimc Configuration
Server /cimc # scope import-export
 Server /cimc/import-export #
Importing a Cimc Configuration
Server# scope cimc Enters the Cimc command mode
 Generating Non maskable Interrupts to the Host
 181
 182
 Bios Parameters by Server Model
Main Bios Parameters for C22 and C24 Servers
C22 and C24 Servers
TPM Support
 Advanced Bios Parameters for C22 and C24 Servers
Processor Configuration Parameters Name
Number of Enabled Cores
Execute Disable
 Intel VT
Intel VT-d
Intel VT-d Coherency Support
Intel VT-d ATS Support
 Adjacent Cache Line Prefetcher
CPU Performance
Hardware Prefetcher
 DCU IP Prefetcher
Direct Cache Access Support
DCU Streamer Prefetch
 Power Technology
 Processor Power State C6
Processor Power State C1 Enhanced
Intel Turbo Boost Technology
Frequency Floor Override
 State Coordination
Energy Performance
 Dram Clock Throttling
Memory Configuration Parameters Name Description
Select Memory RAS
 Low Voltage DDR Mode
Dram Refresh rate
Channel Interleaving
Rank Interleaving
 Altitude
Patrol Scrub
Demand Scrub
 Onboard Storage Parameters Name
QPI Configuration Parameters Name Description
USB Configuration Parameters Name Description
 All USB Devices
USB Port Rear
USB Port Front
USB Port Internal
 PCI Configuration Parameters Name Description
Mmio Above 4GB
Aspm Support
VGA Priority
 Bits per second
Console Redirection
Terminal Type
 Flow Control
Putty KeyPad
 All Onboard LOM Ports
LOM Port n OptionROM
All PCIe Slots OptionROM
PCIe Slot n OptionROM
 Server Management Bios Parameters for C22 and C24 Servers
FRB-2 Timer
OS Watchdog Timer
PCIe Slot n Link Speed
 OS Watchdog Timer Timeout
OS Watchdog Timer Policy
 Boot Order Rules
 C220 and C240 Servers
Main Bios Parameters for C220 and C240 Servers
Advanced Bios Parameters for C220 and C240 Servers
 204
 Disabled -The processor does not support ATS
Enabled -The processor uses VT-d ATS as required
 206
 207
 Power consumption but may reduce system performance
 209
 210
 211
 212
 213
 214
 4GB or greater address space
USB Port SD Card
Memory Mapped I/O Above 4GB
 Offboard -Priority is given to the Pcie Graphics adapter
Enables console redirection on COM port 0 during Post
Enables console redirection on COM port 1 during Post
 Allows you to change the action of the PuTTY function keys
Introduced by a hidden terminal problem. This can be one
None -No flow control is used
 218
 If it hangs during POST. This can be one of the following
Server Management Bios Parameters for C220 and C240 Servers
PCIe Mezzanine OptionROM
 Watchdog timer expires 5 minutes after the OS
 System removes that device type from the boot order
 Main Bios Parameters for C260 Servers
Advanced Bios Parameters for C260 Servers
Processor Configuration Parameters Name Description
C260 Servers
 Enhanced Intel Speedstep Technology
Whether the processor uses Enhanced Intel SpeedStep
Intel Hyper-Threading Technology
Which allows multithreaded software applications to execute
 Intel VT-d Interrupt Remapping
Intel Virtualization Technology
Intel VT for Directed IO
 Direct Cache Access
Processor C3 Report
 CPU C State
Processor C6 Report
Package C State Limit
 Numa Optimized
 Sparing Mode
Mirroring Mode
Sparing
Mirroring
 Serial Port Configuration Parameters Name Description
Serial a Enable
USB Configuration Parameters Name
Patrol Scrub Interval
 Onboard NIC n ROM
PCIe OptionROMs
PCIe Slot n ROM
Onboard Gbit LOM
 IOH Resource Allocation
Onboard 10Gbit LOM
Sriov
 Assert NMI on Perr
Server Management Bios Parameters for C260 Servers
Assert NMI on Serr
 OS Boot Watchdog Timer Timeout
Baud Rate
 Legacy OS Redirection
OS Boot Watchdog Policy
OS Boot Watchdog Timer
 C420 Servers
Main Bios Parameters for C420 Servers
Advanced Bios Parameters for C420 Servers
 236
 237
 238
 239
 240
 241
 242
 243
 244
 245
 Not detected by the Bios and operating system
Enabled -Enables the SD card drives
 247
 Can be one of the following
 Allows you to change the action of the PuTTY function keys
 250
 Server Management Bios Parameters for C420 Servers
 252
 C460 Servers
Main Bios Parameters for C460 Servers
Advanced Bios Parameters for C460 Servers
 254
 255
 Intel VT-d PassThrough DMA
 257
 258
 259
 260
 261
 262
 Server Management Bios Parameters for C460 Servers
 264
 265
 266
 D E
 Installing from remote server 159 obtaining from Cisco
 Dedicated
LDAP, See Active Directory local users
 IN-4
 Yaml
 IN-6