Cisco Systems UCSCPCIEBTG, 57712 manual Making a Global Hot Spare, Preparing a Drive for Removal

Models: 57712 UCSCPCIEBTG

1 288
Download 288 pages 20.54 Kb
Page 138
Image 138

Managing Network Adapters

Making a Global Hot Spare

Server /chassis/storageadapter # scope physical-drive 3

Server /chassis/storageadapter/physical-drive # make-dedicated-hot-spare

5:VD_OS_1, RAID 0, 102400 MB, physical disks: 1

6:VD_OS_2, RAID 0, 12288 MB, physical disks: 1

7:VD_OS_3, RAID 0, 12288 MB, physical disks: 1

8:VD_DATA_1, RAID 0, 12512 MB, physical disks: 1

9:RAID1_2358, RAID 1, 40000 MB, physical disks: 2,3,5,8

11:JFB_RAID1_67, RAID 1, 20000 MB, physical disks: 6,7

12:JFB_Crv_R1_40, RAID 1, 40000 MB, physical disks: 6,7

13:JFB_R1_10GB, RAID 1, 10000 MB, physical disks: 6,7

Please choose from the above 8 virtual drives-->6

Server /chassis/storageadapter/physical-drive #

Making a Global Hot Spare

Before You Begin

You must log in with admin privileges to perform this task.

Procedure

 

Command or Action

Purpose

Step 1

Server# scope chassis

Enters the chassis command mode.

Step 2

Server /chassis # scope storageadapter slot

Enters command mode for an installed

 

 

storage card.

Step 3

Server /chassis/storageadapter # scope

Enters command mode for the specified

 

physical-drive drive-number

physical drive.

Step 4

Server /chassis/storageadapter/physical-drive #

 

 

make-global-hot-spare

 

Step 5

Server /chassis/storageadapter/physical-drive #

Displays the status of the task that is in

 

get-operation-status

progress on the drive.

This example shows how to make physical drive 3 a global hot spare:

Server# scope chassis

Server /chassis # scope storageadapter SLOT-3

Server /chassis/storageadapter # scope physical-drive 3

Server /chassis/storageadapter/physical-drive # make-global-hot-spare

Server /chassis/storageadapter/physical-drive #

Preparing a Drive for Removal

You can confirm this task only on physical drives that display the Unconfigured Good status.

Before You Begin

You must log in with admin privileges to perform this task.

 

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

122

OL-28893-01

Page 138
Image 138
Cisco Systems UCSCPCIEBTG, 57712 manual Making a Global Hot Spare, Preparing a Drive for Removal, Make-global-hot-spare