BIOS Parameters by Server Model

Advanced BIOS Parameters for C260 Servers

Name

Description

Patrol Scrub Interval

Controls the time interval between each patrol scrub memory

 

access. A lower interval scrubs the memory more often but

 

requires more memory bandwidth.

 

Select a value between 5 and 23. The default value is 8.

 

Note

This option is used only if Patrol Scrub is

 

 

enabled.

CKE Low Policy

Controls the DIMM power savings mode policy. This can be

 

one of the following:

DisabledDIMMs do not enter power saving mode.

SlowDIMMs can enter power saving mode, but the requirements are higher. Therefore, DIMMs enter power saving mode less frequently.

FastDIMMs enter power saving mode as often as possible.

AutoThe BIOS controls when a DIMM enters power saving mode based on the DIMM configuration.

Serial Port Configuration Parameters

Name

Description

Serial A Enable

Whether serial port A is enabled or disabled. This can be one of the

 

following:

DisabledThe serial port is disabled.

EnabledThe serial port is enabled.

USB Configuration Parameters

 

Name

Description

Make Device Non-BootableWhether the server can boot from a USB device. This can be one of the following:

DisabledThe server can boot from a USB device.

EnabledThe server cannot boot from a USB device.