Managing Server Power

Powering On the Server

Ifthe server was powered off other than through the CIMC, the server will not become active immediately
whenpowered on. In this case, the server will enter standby mode until the CIMC completes initialization.
Note
Ifany firmware or BIOS updates are in progress, do not change the server power until those tasks are
complete.
Important
Before You Begin
Youmust log in with user or admin privileges to perform this task.
Procedure
PurposeCommand or Action
Enterschassis command mode.Server#scope chassis
Step 1
Turnson the server.Server/chassis # power on
Step 2
Thisexample turns onthe server:
Server# scope chassis
Server /chassis # power on
This operation will change the server's power state.
Continue?[y|N]y
Server /chassis # show
Power Serial Number Product Name UUID
----- ------------- ------------- ------------------------------------
on Not Specified Not Specified 208F0100020F000000BEA80000DEAD00

Powering Off the Server

Ifany firmware or BIOS updates are in progress, do not power off the server until those tasks are complete.Important
Before You Begin
Youmust log in with user or admin privileges to perform this task.
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
18 OL-28893-01
Managing the Server
Managing Server Power