Managing Network Adapters

Disabling Auto Learn Cycles for the Battery Backup Unit

This example shows how to enable the battery auto-learn cycles:

Server # scope chassis

Server /chassis # scope storageadapter SLOT-2Server /chassis/storageadapter # scope bbu

Server /chassis/storageadapter/bbu # enable-auto-learnAutomatic BBU learn cycles will occur without notice if enabled. Are you sure? [y/n] --> y

enable-auto-learn initiated

Server /chassis/storageadapter/bbu #

Disabling Auto Learn Cycles for the Battery Backup Unit

Before You Begin

You must log in with admin privileges to perform this task.

Procedure

 

Command or Action

Purpose

Step 1

Server# scope chassis

Enters the chassis command mode.

Step 2

Server /chassis # scope storageadapter slot

Enters command mode for an installed storage

 

 

card.

Step 3

Server /chassis/storageadapter # scope bbu

Enter the battery backup unit command mode.

Step 4

Server /chassis/storageadapter #

Disables the battery auto-learn cycles

 

disable-auto-learn

 

This example shows how to disables the battery auto-learn cycles:

Server # scope chassis

Server /chassis # scope storageadapter SLOT-2Server /chassis/storageadapter # scope bbu

Server /chassis/storageadapter/bbu # disable-auto-learnAutomatic BBU learn cycles will no longer occur if disabled. Are you sure? [y/n] --> y

disable-auto-learn initiated

Server /chassis/storageadapter/bbu #

Starting a Learn Cycle for a Battery Backup Unit

Before You Begin

You must be logged in as an admin to use this command.

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

OL-28893-01

125

Page 141
Image 141
Cisco Systems 57712, UCSCPCIEBTG manual Disabling Auto Learn Cycles for the Battery Backup Unit, Disable-auto-learn