Image 169

Configuring Platform Event Filters

Interpreting Platform Event Traps

This example configures general platform event trap settings and trap destination number 1 and commits the transaction:

Server# scope

fault

Server

/fault

# scope pef-destination 1

Server

/fault

/pef-destinations *# set enabled yes

Server

/fault

/pef-destinations *# set addr 1.2.3.4

Server

/fault

/pef-destinations *# commit

Server

/fault

/pef-destinations # show

Trap Destination 1:

IP

Address: 1.2.3.4

Enabled: yes

Server

/fault

/pef-destinations #

Interpreting Platform Event Traps

A CIMC platform event alert contains an enterprise object identifier (OID) in the form 1.3.6.1.4.1.3183.1.1.0.event. The first ten fields of the OID represent the following information:

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).wired_for_management(3183).PET(1).version(1).version(0),

indicating an IPMI platform event trap (PET) version 1.0 message. The last field is an event number, indicating the specific condition or alert being notified.

Platform Event Trap Descriptions

The following table provides a description of the event being notified in a platform event trap message, based on the event number in the trap OID.

Event Number [Note 1]

Platform Event Description

0

0h

Test Trap

65799

010107h

Temperature Warning

65801

010109h

Temperature Critical

131330

020102h

Under Voltage, Critical

131337

020109h

Voltage Critical

196871

030107h

Current Warning

262402

040102h

Fan Critical

459776

070400h

Processor related (IOH-Thermalert/Caterr sensor) predictive failure

 

 

deasserted

459777

070401h

Processor related (IOH-Thermalert/Caterr sensor) predictive failure

 

 

asserted

460032

070500h

Processor Power Warning limit not exceeded

460033

070501h

Processor Power Warning limit exceeded

524533

0800F5h

Power Supply Critical

524551

080107h

Power Supply Warning

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5

OL-28893-01

153

Page 169