Procedure 2. Al Front Frame/Al8 CRT

A18Wl

F

SK126

Figure 3-5. Installing the CRT and Front-Frame Assemblies

Replacement

Note

Use care when handling the glass CRT EM1 shield. The glass may be cleaned

 

using thin-film cleaner (HP part number 8500-2163) and a lint-free cloth.

 

When installing the glass shield, face the side of the glass with the silver

 

coated edge towards the inside of the analyzer.

 

 

1.Place the analyzer on its right-side frame with the front end extending slightly over the front of the work bench.

2.Gently place the A18 CRT assembly into the Al Front-Frame assembly as llustrated in Figure 3-6.

3.Place the front-frame and CRT assemblies into the analyzer, using caution to avoid pinching any cables.

4.Dress the AlBWl trace-align wires between the CRT assembly mounts and the A6 Power Supply top shield.

3-8 Assembly Replacement