A2

CONTROLLER

(TAM TEST

SPi7

CONNECTOR)

Figure 9-1. A2 Test Connectors

10.Press SOFT KEY #4. The results will be sent to the printer.

11.If a failure is indicated in any of these tests, the fault lies on the A2 Controller assembly. To obtain more information:

a.Press the down arrow key one less time than the test number. (For example, press it twice for the third test on the list.)

b. Press SOFT KEY t3 , then SOFT KEY 64, and when the printout is complete, SOFT KEY #6.

12.If no failures were indicated in testing the A2 Controller, move the probe cable to A17J4.

13.Press SOFT KEY #I and wait five seconds.

14.Press SOFT KEY #4 . The results will be sent to the printer.

15.If no failure is indicated in the printout, refer to “High Voltage Supplies” in Chapter 12.

Controller Section 9-3