3.Check for a 3
4.Check that the signal at A15J301 is 10 MHz 640 Hz (with TCXO reference) using a frequency counter. If necessary, perform the appropriate 10 MHz reference adjustment.
5.If there is no problem with INTernal 10 MHz reference operation, check EXTernal 10 MHz reference operation as follows:
6.Set the HP 8560A’s 10 MHz reference to external by pressing 10 MHz EXT .
7.Connect a 10 MHz,
8.Check the signals at A15J301, A155302, A15J303, and A15J304 according to the procedure in steps 2 through 4.
9.If the signals are correct in EXTernal operation, but not in INTernal operation, the problem lies in the TCXO, its voltage reference, the TTL level generator, or the A21 OCXO, if Option 003. Check these sections as follows:
On the HP 8560A, press 10 MHz INT .
Check U305 pin 3 for approximately +12 Vdc.
Check for a 10 MHz sine wave, 21
10.If the signal at U303 pin 5 is correct (see Figure
G r a p h I 1 1 | 1 0 0 V/div | 0 00 v | 5 0 0 ns/div | 0 000 s |
|
|
|
|
|
1 : [Char- 1 1
u301 P I N9
Figure
RF Section 1