Synchronous Detector
A wide dynamic range linear detector is realized by the Limiter (block G), the Isolation Amplifier (block H), the LO Amplifier (block I), and the Detector/Mixer (block J). The combination of these circuits form what is commonly known as a synchronous detector.
The input signal is split between two paths. One path flows through the Isolation Amplifier and the other path flows through the Limiter and LO Amplifier The path flowing through the limiter generates the LO for the Detector/Mixer block. The path through the Isolation Amplifier drives the RF port.
To troubleshoot this group of circuits set the RBW to 300 kHz. Inject 10.7 MHz at +6 dbm into J3. Probe the gate of A4Q404 or A4Q405 with a scope. Look for a 0 to
The signals at the gates of A4Q404 and A4Q405 should be 180 degrees out of phase from each other. If they are not 180 degrees out of phase or one of the signals are not present, troubleshoot the LO Amplifier or the FET’s in the mixer. If the signal is not a symmetrical square wave, troubleshoot the LO amplifier. If the signal drops out prematurely or is not present at all, troubleshoot the limiter or LO amplifier.
Repeat the procedure for an RBW 2 100 kHz. If the log amplifier works in the 300 kHz RBW but not in the narrower RBWs, troubleshoot the log narrow filter in the limiter or isolation amplifier. A4CR302 and A4CR303 are varactor diodes in the limiter filter and are used to tune the filter.
Limiter
Refer to function block G of A4 Log Amplifier Schematic Diagram (sheet 2 of 4) in the HP 856OA/61B/63A Spectrum Analyzer Component Level Information binder.
The Limiter consists of 7 identical 20 dB gain stages. A “log narrow filter” is switched in for RBWs 5100 kHz. This filter is switched in using the control lines NARROW between the 4th and 5th stages. During normal operation, the limiter serves to amplify even the smallest 10.7 MHz signals up to a level sufficient to drive the LO Amplifier and subsequent Detector/Mixer. This signal serves as the LO for the mixer circuitry.
Isolation Amplifier
Refer to function block H of A4 Log Amplifier Schematic Diagram (sheet 3 of 4) in the HP 856OA/61B/63A Spectrum Analyzer Component Level Information binder.
The isolation amplifier prevents LO port to RF port feedthrough in the mixer from feeding back to the input of the limiter and causing loop oscillations. In addition, the isolation amplifier matches the phase of the
Detector/Mixer
Refer to function block J of A4 Log Amplifier Schematic Diagram (sheet 3 of 4) in the HP 856OA/61B/63A Spectrum Analyzer Component Level Information binder.