Lexmark IBM 9077 manual On page 212 shows the IP addresses used in our configuration

Models: IBM 9077

1 342
Download 342 pages 50.2 Kb
Page 229
Image 229

If ARP is disabled on the SP Switch network, the IP addresses assigned to the nodes must be determined by the switch node numbers.

Note: The SP Switch Router Adapter card will not properly forward IP data to nodes assigned with an IP address that is in another subnet.

Configuration:

In this scenario, we have the SP Switch of SP21 connected to the GRF 1600. The GRF 1600 has its ATM OC-3c media card’s port 00 connected to the GRF 400 ATM OC-3c media card’s port 00. The GRF 400 in turn is attached to the SP Switch of SP2, as shown in Figure 68 and Table 23 on page 212. The netmask for all interfaces is 255.255.255.0.

 

SP

 

Net 192.168.13.0

Net 10.1.1.2

Switch

 

 

ATM OC-3c

Router 1

IP 192.168.13.4

SP processor node

Adapter card

 

SP Switch Router

SP Switch 1

 

 

 

 

Adapter card 1

SP2

 

 

Mask 255.255.255.0

 

GRF 400

SP processor node

 

 

 

 

 

 

Mask 255.255.255.0

 

SP

 

Net 192.168.14.0

Net 10.1.1.1

Switch

 

 

 

Router 2

IP 192.168.14.4

SP processor node

ATM OC-3c

 

SP Switch Router

SP Switch 2

Adapter card

 

 

 

 

Adapter card 2

SP21

 

 

Mask 255.255.255.0

 

 

SP processor node

 

GRF 1600

 

 

Figure 68. SP Switch - ATM - SP Switch Connection

Table 23 on page 212 shows the IP addresses used in our configuration.

Multiple RS/6000 SPs and Multiple GRFs 211

Page 229
Image 229
Lexmark IBM 9077 manual On page 212 shows the IP addresses used in our configuration