Lexmark IBM 9077 SP Switch Pool Size Settings, 255, Network Options of CWS and All Nodes Part 3

Models: IBM 9077

1 342
Download 342 pages 50.2 Kb
Page 273
Image 273

Table 48. Network Options of CWS and All Nodes Part 3 of 3

Parameters

Value

 

 

ipignoreredirects

0

 

 

ipsrcroutesend

1

 

 

ipsrcrouterecv

1

 

 

ipsrcrouteforward

1

 

 

ip6srcrouteforward

1

 

 

ip6_defttl

64

 

 

ndpt_keep

120

 

 

ndpt_reachable

30

 

 

ndpt_retrans

1

 

 

ndpt_probe

5

 

 

ndpt_down

3

 

 

ndp_umaxtries

3

 

 

ndp_mmaxtries

3

 

 

ip6_prune

2

 

 

tcp_timewait

1

 

 

tcp_ephemeral_low

32768

 

 

tcp_ephemeral_high

65535

 

 

udp_ephemeral_low

32768

 

 

udp_ephemeral_high

65535

 

 

A.2 SP Switch Pool Size Settings

Two important switch parameters were changed from their default values: rpoolsize and spoolsize. To check the current values, enter:

lsattr -El css0

and look for rpoolsize and spoolsize. 512 KB per processor is the default size. Both values should be increased if high I/O traffic is expected on the SP Switch. To increase both values to 5 MB (as applied in all of our scenarios), enter:

/usr/lib/methods/chgcss -l css0 -a spoolsize=5242880 -a rpoolsize=5242880

For the changes to take effect, the SP nodes must be rebooted.