Lexmark IBM 9077 manual File /etc/grarp.conf has the following entry I-field

Models: IBM 9077

1 342
Download 342 pages 50.2 Kb
Page 247
Image 247

The media card adapters on the GRF routers should already be up and running (according to Section 3.7, “Step-by-Step Media Card Configuration” on page 86 and Section 4.5, “HIPPI Configuration” on page 133). Important settings are repeated here, nevertheless, to be on the safe side:

On the GRF 1600 (HIPPI card is in slot 8, SP Switch card is in slot 3) check for the following:

1. The file /etc/grifconfig.conf has the following entries:

gh080

10.50.1.1

255.255.255.0

-

mtu

65280

gt030

192.168.14.4

255.255.255.0

-

mtu

65520

2.The file /etc/grlamap.conf has the following entry (note that ’0x40’ is a hexadecimal value equivalent to 64 decimal):

*

0xfc0 0x40

# default mapping of IP for all portcards

3. The file /etc/grarp.conf has the following entry (I-field):

gh080

10.50.1.2

0x03666fc0

4.The file /etc/grroute.conf has the following line:

192.168.13.0 255.255.255.0 10.50.1.2

This sets the correct route to the other SP Switch network over the HIPPI interface automatically; of course, this route can also be set manually every time the GRF is rebooted.

5.The SP Switch Router Adapter card is connected to the SP Switch and configured. Check with SDRGetObjects switch_responds on the CWS and use Eunfence if needed.

On the GRF 400 (HIPPI card is in slot 0, SP Switch card is in slot 1):

1. The file /etc/grifconfig.conf has the following entries:

gh000

10.50.1.2

255.255.255.0

-

mtu

65280

gt010

192.168.13.4

255.255.255.0

-

mtu

65520

2. The file /etc/grlamap.conf has the following entry:

*

0xfc0 0x40

# default mapping of IP for all portcards

3. The file /etc/grarp.conf has the following entry (I-field):

gh000

10.50.1.1

0x03555fc0

4.The file /etc/grroute.conf has the following line:

192.168.14.0 255.255.255.0 10.50.1.1

This sets the correct route to the other SP Switch network over the ATM interface automatically; of course, this route could also be set manually every time the GRF is rebooted.

Multiple RS/6000 SPs and Multiple GRFs 229

Page 247
Image 247
Lexmark IBM 9077 manual File /etc/grarp.conf has the following entry I-field