Lexmark IBM 9077 manual SP Switch Fddi Connection

Models: IBM 9077

1 342
Download 342 pages 50.2 Kb
Page 180
Image 180

0)f50:/itso/space 32$ ftp 192.168.14.1 Connected to 192.168.14.1.

220 sp21n01 FTP server (Version 4.1 Tue Mar 17 14:00:13 CST 1998) ready. Name (192.168.14.1:root): root

331 Password required for root. Password:

230 User root logged in. ftp> bin

200 Type set to I.

ftp> put bos.obj.ssp.itso /dev/null 200 PORT command successful.

150 Opening data connection for /dev/null.

226 Transfer complete.

299878400 bytes sent in 31.95 seconds (9166 Kbytes/s) local: bos.obj.ssp.itso remote: /dev/null

ftp> quit

221Goodbye. (0)f50:/itso/space 33$

As you see in the screen shot, the F50’s 9.2 MB/s comes very close to the theoretical maximum throughput of about 10-11 MB/s. So we decided to put some stress on the network, as follows:

On two SP21 nodes, we started ftp put commands to the F50, while the F50 was busy, putting data to other SP21 nodes, and observed an aggregate throughput over the Ethernet adapter of up to 15 MB/s, with more than 35% collision on the Ethernet and the F50 23% busy.

5.1.2 SP Switch - FDDI Connection

This is quite an easy scenario. It is used to connect workstations equipped with an FDDI interface card, FDDI hubs, and similar FDDI network devices to the SP Switch.

Configuration assumptions:

The SP Switch Router FDDI media card was installed according to Section 4.4, “FDDI Configuration” on page 121, and works properly.

The SP Switch Router Adapter card was installed according to Section 3.7, “Step-by-Step Media Card Configuration” on page 86, and works properly.

The SP Switch Router Adapter card and SP processor node Switch adapters are in the same IP subnet.

ARP should be enabled on the SP Switch network to provide the most flexibility in assigning IP addresses (strongly recommended!).

162IBM 9077 SP Switch Router: Get Connected to the SP Switch

Page 180
Image 180
Lexmark IBM 9077 manual SP Switch Fddi Connection