2 Troubleshooting Procedures

2.7 Keyboard and Touch pad Troubleshooting

Check 4 The touch pad or the touch pad cable may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures. If the problem still exists, perform Check 7.

Check 5 Make sure the cable of the Sensor/Switch board is firmly connected to PJ1000 on the system board, and the sensor/switch board cable is connected to PJ3200 on the sensor/switch board.

Sensor/Switch

Board

PJ3200

If the connection is loose, reconnect firmly and repeat Procedure 1. If there is still an error, go to Check 6.

Check 6 The Sensor/Switch board may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures. If there is still an error, go to Check 7.

Check 7 The system board may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures.