2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
Check 1 Compare the patterns in the hexadecimal error code to the tables below.
q DC IN
Error code | Meaning |
|
|
10h | AC Adaptor output voltage is over 16.5V. |
|
|
11h | Common Dock voltage is over 16.5V. |
|
|
12h | Current from the DC power supply is over 6.05A. |
|
|
13h | Current from the DC power supply is over 0.5A when there is no load. |
|
|
14h | Current sensing IC is not normal. |
|
|
q 1st Battery
Error code | Meaning |
|
|
20h | Main battery charge current is more than 6.05 A. |
|
|
21h | Main battery charge current is over 6.05A. |
|
|
22h | Main battery discharge current over 0.5A. |
|
|
23h | Main battery charge current is over 4.3A. |
|
|
24h | Current sensing IC is not normal. |
|
|
25h | Main battery charge current is over 0.3A. |
|
|
q 2nd Battery
Error code | Meaning |
|
|
30h | Overvoltage is detected. (Not supported) |
|
|
31h | Main battery charge current is over 6.05A. |
|
|
32h | Main battery discharge current is over 0.5A. |
|
|
33h | Main battery charge current is over 3. 1A. |
|
|
34h | Current sensing IC is not normal. |
|
|
35h | Secondary battery charge current is over 0. 3A. |
|
|
TECRA M1 Maintenance Manual (960 |