Toshiba M1 manual 1st Battery, Error code Meaning

Models: M1

1 426
Download 426 pages 50.3 Kb
Page 68
Image 68

2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

Check 1 Compare the patterns in the hexadecimal error code to the tables below.

q DC IN

Error code

Meaning

 

 

10h

AC Adaptor output voltage is over 16.5V.

 

 

11h

Common Dock voltage is over 16.5V.

 

 

12h

Current from the DC power supply is over 6.05A.

 

 

13h

Current from the DC power supply is over 0.5A when there is no load.

 

 

14h

Current sensing IC is not normal.

 

 

q 1st Battery

Error code

Meaning

 

 

20h

Main battery charge current is more than 6.05 A.

 

 

21h

Main battery charge current is over 6.05A.

 

 

22h

Main battery discharge current over 0.5A.

 

 

23h

Main battery charge current is over 4.3A.

 

 

24h

Current sensing IC is not normal.

 

 

25h

Main battery charge current is over 0.3A.

 

 

q 2nd Battery

Error code

Meaning

 

 

30h

Overvoltage is detected. (Not supported)

 

 

31h

Main battery charge current is over 6.05A.

 

 

32h

Main battery discharge current is over 0.5A.

 

 

33h

Main battery charge current is over 3. 1A.

 

 

34h

Current sensing IC is not normal.

 

 

35h

Secondary battery charge current is over 0. 3A.

 

 

2-8

TECRA M1 Maintenance Manual (960 -436)

Page 68
Image 68
Toshiba M1 manual 1st Battery, Error code Meaning