3 Tests and Diagnostics

3.25 Log Utilities

3.25 Log Utilities

3.25.1Function Description

This function logs error information generated while a test is in progress and stores the results in RAM. This function can store data on a floppy disk or output the data to a printer. If the power switch is turned off, the error information will be lost. The error information is displayed in the following order:

1.Error count (CNT)

2.Test name (TS -NAME)

3.Subtest number (TS -NAME)

4.Pass count (PASS)

5.Error status (STS)

6.FDD/HDD or memory address (ADDR)

7.Write data (WD)

8.Read data (RD)

9.HDC status (HSTS)

10.Error status name (ERROR STATUS NAME)

3.25.2Operations

Selecting 5 and pressing Enter in the DIAGNOSTIC MENU, logs error information into RAM or onto a floppy disk. The error information is displayed in the following format:

XXXXX ERRORS

CNT TS-NO PASS STS ADDR

WD RD HSTS

[ERROR STATUS NAME]

001 EXP01 0000 XXX 00000000 00 00 0000

FDD-WRITE PROTECTED

001 EXP03 0000 XXX 00000000 00 00 0000

FDD-TIME OUT ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

 

 

 

 

 

 

 

 

Error status

 

 

 

 

 

 

 

 

 

 

 

 

HDC status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass count

 

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

Subtest number

 

 

 

 

 

Error status name

 

 

 

 

 

 

 

 

Write data

 

Test name

 

 

 

 

 

 

 

 

 

 

Error count

 

 

 

 

 

 

 

 

[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]

3-68

TECRA M1 Maintenance Manual (960 -436)

Page 195
Image 195
Toshiba M1 manual Tests and Diagnostics Log Utilities