4 Replacement Procedure | 4.25 Fluorescent Lamp |
4.25.2 Replacing the
CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid contaminating or damaging the LCD panel. Be careful not to let dust or other foreign substance into the module.
Disassembling the
To disassemble the
1.Turn the LCD module face down, and remove the protection cover S (A), protection cover G (B), aluminum tape (C) and fixing tape for lead wire (D).
NOTE: 1) Be careful not to damage the TCP or chips.
2) Discard the tapes removed.