4 Replacement Procedure

4.25 Fluorescent Lamp

4.25.2 Replacing the 14.1-inch SXGA+ Sharp Fluorescent Lamp

CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid contaminating or damaging the LCD panel. Be careful not to let dust or other foreign substance into the module.

Disassembling the 14.1-inch SXGA+ Sharp Fluorescent Lamp

To disassemble the 14.1-inch SXGA+ Sharp fluorescent lamp, follow the steps below and refer to figures4-62 to 4-71.

1.Turn the LCD module face down, and remove the protection cover S (A), protection cover G (B), aluminum tape (C) and fixing tape for lead wire (D).

NOTE: 1) Be careful not to damage the TCP or chips.

2) Discard the tapes removed.

4-100