3.6 Keyboard Test

3 Tests and Diagnostics

Subtest 03

PS/2 Mouse Connect Check

 

 

 

 

 

NOTE: To execute the PS/2 mouse connect check, a PS/2 mouse must be

 

 

connected to the computer before the power is turned on.

 

 

 

 

This subtest checks whether a PS/2 mouse is connected or not.

 

If this test does not detect an error, it returns to the subtest menu.

 

If this test detects an error, the following message appears.

 

DATA COMPARE ERROR

 

 

[[ HALT OPERATION ]]

 

 

1: Test end

 

 

2: Continue

 

 

3: Retry

Subtest 04

Touch Pad/IPS

 

This subtest checks the functions of the pointing stick as shown below.

 

A) Touch Pad/IPS stick pressure sensing direction and parameter.

 

B) Touch Pad/IPS switch function check.

 

This test reports the pointing stick motion response from the IPS and IPS switch.

 

When the stick is pressed towards the upper left, the <DIRECTION> display

 

changes according to the following illustration. If an IPS switch is pressed, the

 

<LAT> displays appear on the right side one by one. The parameters appear on

 

the center of the display. To exit this subtest, press the four IPS switches at the

 

same time.