INSTALLATION | |||||||
SAFETY PRECAUTIONS | LIFTING |
| |||||
|
|
|
|
|
|
| |
|
|
|
| WARNING |
| Lift the machine by the lift bail only. | The lift bail is |
|
|
|
|
|
| designed to lift the power source only. Do not | |
|
|
| ELECTRIC SHOCK | attempt to lift the Power Wave with accessories | |||
|
|
| |||||
|
|
| attached to it. |
| |||
|
|
| can kill. |
| |||
|
|
|
|
| |||
|
|
| • | Only qualified personnel should per- |
|
| |
|
|
|
| form this installation. | FEEDER AND CONTROL BOX | ||
|
|
| • | Turn off the input power to the power | MOUNTING |
| |
|
|
|
| source at the disconnect switch or |
|
| |
|
|
|
| fuse box before working on this equip- | SEPARATION FROM BENCH MODEL | ||
|
|
|
| ment. Turn off the input power to any | |||
|
|
|
|
|
| ||
|
|
|
| other equipment connected to the | The Control Box can be removed from the bench | ||
|
|
|
| welding system at the disconnect | |||
|
|
|
| model feeder and mounted in a different location. | |||
|
|
|
| switch or fuse box before working on | |||
|
|
|
| See Figure |
| ||
|
|
|
| this equipment. |
| ||
|
|
|
|
|
| ||
|
|
| • | Do not touch electrically hot parts. | FIGURE A.1 — SEPARATING CONTROL BOX | ||
|
|
|
|
|
| AND FEEDER. |
|
Return to
Return to Section TOC
•Always connect the Power Wave grounding lug (located inside the reconnect input access door) to a proper safety (Earth) ground.
LOCATION AND MOUNTING
Place the welder where clean cooling air can freely circulate in through the rear louvers and out through the case sides and bottom. Dirt, dust, or any foreign material that can be drawn into the welder should be kept at a minimum. Using filters on the air intake to prevent dirt from building up restricts air flow. Do not use such filters. Failure to observe these precau- tions can result in excessive operating temperatures and nuisance shutdowns.
WIRE
CONTROLDRIVE
BOX
CENTERCONNECTOR
PANEL
MOUNTING
SCREW
BOTTOM
PANEL
Complete the following steps to remove the Control Box:
STACKING
Power Wave machines can be stacked to a maxi- mum of three high. The bottom machine must always be placed on a firm, secure, level surface. There is a danger of machines toppling over if this precaution is not taken.
1.Remove the bottom and center option panels from the front of the Control Box.
2.Disconnect the connector between the Control Box and the wire drive located in the middle of the Control Box back near the bottom of the Control Box.
Return to Section TOC
Return to Master TOC
ENVIRONMENT
The Power Wave power source carries an IP21 envi- ronmental rating. If subjected to occasional falling water, such as rain, the machine should be sheltered.
POWER WAVE 455/POWER FEED 10