Lincoln Electric SVM135-B Input Cable Assemblies, Cable Receptacles, Receptacle Output

Models: SVM135-B

1 182
Download 182 pages 15.74 Kb
Page 36
Image 36

C-4

ACCESSORIES

C-4

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

INPUT CABLE ASSEMBLIES

K1543 (Control Cable Only) - Consists of a 5-con- ductor control cable with a 5-pin control cable plug, without electrode cable, and is available in lengths of 10 ft, 15 ft, 20 ft, 50 ft, and 100 ft.

K1544 - Consists of a 5-conductor control cable with a 5-pin control cable plug and a 3/0 electrode cable. It is rated at 600 amps, 60% duty cycle and is avail- able in lengths of 10 ft,15 ft, 20 ft, and 50 ft.

With input power disconnected from the power source, install the input cable by performing the following:

CABLE RECEPTACLES

K1548-1 RECEPTACLE KIT (INPUT AND OUTPUT)

This kit contains the contents of both the K1549-1 and K1550-1 kits. Refer to the instructions for each, below.

RECEPTACLE (OUTPUT)

Optional Output Connector installation into the Control Box cabinet and/or into the feed head enclosure.

Control Box Cabinet Procedure

1.Turn off power.

2.Remove the screws from the front of the lower and middle option panels of the Control Box.

3.Tilt the option panels away from the front open- ing of the Control Box cabinet. If the option panel has an electrical connector, disconnect it from the main printed circuit board (note connection point for re-connection later). Remove the option panel and set aside.

4.Remove the plastic plug (black) from the left hole

in the bottom of the Control Box cabinet and store it in the bottom of the Control Box cabinet for future use, should the Optional Output Connector be removed.

5.Place the Optional Output Connector (Amphenol) through the hole opened by the pre- vious step (place from the inside, out). Rotate the Optional Output Connector so its aligning key is positioned to the front of the Control Box cabinet. Fasten the Optional Output Connector to the bottom wall of the Control Box cabinet with the four screws provided.

6.Secure the choke (large circular component of the Optional Output Connector) by inserting its leads into the white nylon clip located near the Optional Output Connector on the back wall of the Control Box cabinet. Insert the choke leads only.

7.The Optional Output Connector has two internal connectors, a four pin, and a single lead connec- tor. Connect the four pin connector to the unused four pin connector on the main printed circuit board. Connect the single lead connector to a similar connector found on a lead nearby that branches out of the Control Box wiring har- ness.

8.Re-install the lower and middle option panels by reversing the removal process. While re- installing the option panels, ensure clearance between Optional Output Connector compo- nents, Control Box wiring harness, and option panel harness (if any).

POWER WAVE 455/POWER FEED 10

Page 36
Image 36
Lincoln Electric SVM135-B service manual Input Cable Assemblies, Cable Receptacles, K1548-1 Receptacle KIT Input and Output