F-37

TROUBLESHOOTING AND REPAIR

F-37

AUXILIARY TRANSFORMER NO. 2 TEST

WARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in dan- ger to the technician or machine operator and will invalidate your factory warran- ty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353(WELD).

------------------------------------------------------------------------------------------------

TEST DESCRIPTION

This test will determine if the correct voltage is being applied to the primary of Auxiliary Transformer No. 2 and also if the correct voltage is being induced on the secondary winding of the transformer.

This procedure takes approximately 10 minutes to perform.

MATERIALS NEEDED

Volt-Ohmmeter (Multimeter) 3/8 in. nutdriver

Wiring diagram

POWER WAVE 455/POWER FEED 10

Page 101
Image 101
Lincoln Electric SVM135-B service manual Auxiliary Transformer no Test