TECHNICAL SPECIFICATIONS – POWER WAVE 455

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AT RATED OUTPUT - THREE PHASE ONLY

 

 

 

Rated Output @

 

Input

 

Rated Output @

 

Input

Input Volts

 

100% Duty Cycle

 

Current

 

60% Duty Cycle

 

Current

208V - 60Hz

 

450A@38V 100%

 

70

 

 

570A@43V 60%

 

87

230V - 60Hz

 

450A@38V 100%

 

65

 

 

570A@43V 60%

 

82

400V - 60Hz

 

450A@38V 100%

 

39

 

 

570A@43V 60%

 

50

460V - 60Hz

 

450A@38V 100%

 

35

 

 

570A@43V 60%

 

48

200V - 50Hz

 

450A@38V 100%

 

72

 

 

500A@40V 60%

 

79

220V - 50Hz

 

450A@38V 100%

 

67

 

 

500A@40V 60%

 

74

400V - 50Hz

 

450A@38V 100%

 

40

 

 

500A@40V 60%

 

45

440V - 50Hz

 

450A@38V 100%

 

36

 

 

500A@40V 60%

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

Open

 

 

Pulse

 

 

Pulse

 

Pulse and

 

Circuit

 

 

 

 

Voltage

 

Background

Auxiliary

Voltage

Current Range

Frequency

 

 

Range

 

Time Range

Power

 

 

 

 

 

 

 

 

 

75 VDC

5 - 570

0.15 - 1000 Hz

 

 

5 - 55 VDC

 

100 MICRO SEC. -

40 VDC AT

 

 

 

 

 

 

 

 

 

 

3.3 SEC.

10 AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC AT

 

 

 

 

 

 

 

 

 

 

 

 

 

10 AMPS

 

 

 

 

 

 

 

 

 

 

Process Current Ranges (DC)

 

 

 

 

 

Current

 

 

 

MIG/MAG

 

 

 

 

 

 

 

50-570 Amps

 

 

 

FCAW

 

 

 

 

 

 

 

40-570 Amps

 

 

 

SMAW

 

 

 

 

 

 

 

30-570 Amps

 

 

 

Pulse

 

 

 

 

 

 

 

5-750 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Type 75°C

Type 75°C

Input

 

 

 

 

 

 

Copper Wire in

 

Ground Wire in

(Super Lag)

Voltage /

 

Duty

Input Ampere Rating

 

Conduit AWG[IEC]

Conduit AWG[IEC]

or Breaker

Frequency

 

Cycle

on Nameplate (AMPS)

 

Sizes (mm2)

 

Sizes (mm2)

Size (AMPS)

208/60/50

100%

70/72

 

 

4 (25)

 

8

(10)

 

80

230/60/50

100%

65/67

 

 

4 (25)

 

8

(10)

 

70

400/60/50

100%

39/40

 

 

8 (10)

 

10

(6)

 

50

460/60/50

100%

35/36

 

 

8 (10)

 

10

(6)

 

40

208/60/50

60%*

87/79

 

 

4 (25)

 

8

(10)

 

90

230/60/50

60%*

82/74

 

 

4 (25)

 

8

(10)

 

90

400/60/50

60%*

50/45

 

 

6 (10)

 

8

(6)

 

60

460/60/50

60%*

48/41

 

 

6 (10)

 

8

(6)

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

26.10 in.

19.86 in.

32.88 in.

250 lbs

663 mm

505 mm

835 mm

114 kg

 

 

 

 

 

TEMPERATURE RANGES

Operating Temperature Range

 

Storage Temperature Range

0°C to 40°C

 

-50°C to 85°C

 

 

 

*At 60% duty cycle with 50Hz input power, the machine is de-rated to 500 Amps at 40V.