Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-3

 

 

INSTALLATION

 

 

 

 

A-3

TECHNICAL SPECIFICATIONS – POWER WAVE 455

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AT RATED OUTPUT - THREE PHASE ONLY

 

 

 

Rated Output @

 

Input

 

Rated Output @

 

Input

Input Volts

 

100% Duty Cycle

 

Current

 

60% Duty Cycle

 

Current

208V - 60Hz

 

450A@38V 100%

 

70

 

 

570A@43V 60%

 

87

230V - 60Hz

 

450A@38V 100%

 

65

 

 

570A@43V 60%

 

82

400V - 60Hz

 

450A@38V 100%

 

39

 

 

570A@43V 60%

 

50

460V - 60Hz

 

450A@38V 100%

 

35

 

 

570A@43V 60%

 

48

200V - 50Hz

 

450A@38V 100%

 

72

 

 

500A@40V 60%

 

79

220V - 50Hz

 

450A@38V 100%

 

67

 

 

500A@40V 60%

 

74

400V - 50Hz

 

450A@38V 100%

 

40

 

 

500A@40V 60%

 

45

440V - 50Hz

 

450A@38V 100%

 

36

 

 

500A@40V 60%

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

Open

 

 

Pulse

 

 

Pulse

 

Pulse and

 

Circuit

 

 

 

 

Voltage

 

Background

Auxiliary

Voltage

Current Range

Frequency

 

 

Range

 

Time Range

Power

 

 

 

 

 

 

 

 

 

75 VDC

5 - 570

0.15 - 1000 Hz

 

 

5 - 55 VDC

 

100 MICRO SEC. -

40 VDC AT

 

 

 

 

 

 

 

 

 

 

3.3 SEC.

10 AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC AT

 

 

 

 

 

 

 

 

 

 

 

 

 

10 AMPS

 

 

 

 

 

 

 

 

 

 

Process Current Ranges (DC)

 

 

 

 

 

Current

 

 

 

MIG/MAG

 

 

 

 

 

 

 

50-570 Amps

 

 

 

FCAW

 

 

 

 

 

 

 

40-570 Amps

 

 

 

SMAW

 

 

 

 

 

 

 

30-570 Amps

 

 

 

Pulse

 

 

 

 

 

 

 

5-750 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Type 75°C

Type 75°C

Input

 

 

 

 

 

 

Copper Wire in

 

Ground Wire in

(Super Lag)

Voltage /

 

Duty

Input Ampere Rating

 

Conduit AWG[IEC]

Conduit AWG[IEC]

or Breaker

Frequency

 

Cycle

on Nameplate (AMPS)

 

Sizes (mm2)

 

Sizes (mm2)

Size (AMPS)

208/60/50

100%

70/72

 

 

4 (25)

 

8

(10)

 

80

230/60/50

100%

65/67

 

 

4 (25)

 

8

(10)

 

70

400/60/50

100%

39/40

 

 

8 (10)

 

10

(6)

 

50

460/60/50

100%

35/36

 

 

8 (10)

 

10

(6)

 

40

208/60/50

60%*

87/79

 

 

4 (25)

 

8

(10)

 

90

230/60/50

60%*

82/74

 

 

4 (25)

 

8

(10)

 

90

400/60/50

60%*

50/45

 

 

6 (10)

 

8

(6)

 

60

460/60/50

60%*

48/41

 

 

6 (10)

 

8

(6)

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

26.10 in.

19.86 in.

32.88 in.

250 lbs

663 mm

505 mm

835 mm

114 kg

 

 

 

 

 

TEMPERATURE RANGES

Operating Temperature Range

 

Storage Temperature Range

0°C to 40°C

 

-50°C to 85°C

 

 

 

*At 60% duty cycle with 50Hz input power, the machine is de-rated to 500 Amps at 40V.

POWER WAVE 455/POWER FEED 10

Page 9
Image 9
Lincoln Electric SVM135-B service manual Technical Specifications Power Wave, Input AT Rated Output Three Phase only